Check 7, Any Error Code on LED?

1. Turn o the 4338B.
2. Turn on the 4338B while watching LEDs on the A2 CPU Board Assembly.
3. Check if the LEDs light in the sequence shown in Figure 4-11.
4. If LEDs light as the sequence, replace the LCD Assembly, otherwise (possibly, \HALT"
doesn't turn o or \BERR" lights) replace the A2 CPU Board Assembly.
Note
When replacing the A2 CPU Board Assembly, refer to \Replacing the A2 CPU
Board Assembly" in Chapter 3 for handling the ROM and EEPROM on the A2
Assembly.