Page 9
Preparation for Use In This Chapter Power Requirements LINE Voltage LINE Frequency Power Consumption To Set Power LINE V oltage Table 1-1. Line Voltage Selection Voltage Selector Line Voltage Required Fuse Preparation for Use...
Page 10
4338B To Set Power LINE Frequency 4338B Operation Manual Line 50 Hz 60 Hz Exit Note Preparation for Use...
Page 11
Operating the 4338B In This Chapter Operating the 4338B...
Page 12
4338B Let's Try|Fully Automatic Measurement Resetting 4338B to its Default Settings Note Auto Measurement indicator Connecting the Test Leads Figure 2-1. Connecting 16338A Test Lead Set Operating the 4338B...
Page 13
4338B Performing a SHORT Correction |Canceling the residual impedance in series with the DUT ShortMeas If \ " is displayed WARNING: Out Of Limit If \ " is displayed WARNING: Improper Correction OVLD OVVOL N.C. Operating the 4338B...
Page 14
4338B Measuring a DUT Test Voltage Limit OVVOL To Set Test Signal Level Hold Level AUTO Operating the 4338B...
Page 15
4338B To Select Measurement Range Auto Range mode |Automatically selecting the optimum measurement range Hold Range Hold Range mode|Holding the measurement range of your choice Hold Range To Select Measurement Parameter Operating the 4338B...
Page 16
4338B To Select Measurement Time Mode Meas Time To Set Averaging Rate|Stabilizing the measurement result Operating the 4338B...
Page 17
4338B To Select Trigger Mode Trigger To Set Trigger Delay Time and Source Delay Time TrigDelay SourceDelay Exit Operating the 4338B...
Page 18
4338B To Use Deviation Measurement Function Setting the Deviation Reference Values RefEnt Selecting the Deviation Mode 1ABS Exit Operating the 4338B...
Page 19
4338B To Use Comparator Function Setting the Limit Values Sorting Comprtr On Comprtr On Operating the 4338B...
Page 20
4338B To Use Contact Check Function |Monitoring the connection of test electrodes and DUT Cont Chk Cont Chk N.C. To Select Display Mode Data Cmprtr Digit Data Cmprtr Digit 2-10 Operating the 4338B...
Page 21
4338B To Select Beeper Mode Beep Fail Pass Exit To Print Measurement Data Setting the Printer Printing Operating the 4338B 2-11...
Page 22
4338B Talk Only Figure 2-2. Printer Output Disabling Printing To Display the Current Settings Measurement Settings 2-12 Operating the 4338B...
Page 23
4338B To Trigger a Measurement 4338B Operation Manual Operating the 4338B 2-13...
Page 24
4338B If Y ou Have a Problem If you nd yourself lost when operating the 4338B To return to the measurement mode Exit To return to the default settings Key Lock If the 4338B does not accept key input: Key Lock Key Lock or \OVLD"...
Page 25
4338B Reference Default Settings FAIL Accessories Available 16064B LED Display/Trigger Box 16338A Test Lead Set Operating the 4338B 2-15...
Page 26
4338B Note SHORT Conguration Figure 2-3. SHORT Conguration for Each Test Leads 2-16 Operating the 4338B...
Page 27
4338B Measurement Range Setting Figure 2-4. Measurement Range Other Topics 4338B Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operation Manual Operating the 4338B 2-17...
Page 29
Measurement Examples In This Chapter Measurement Examples...
Page 30
4338B Testing Contanct of Electromechanical Devices Measuring the Contact Resistance of Switch Requirements Measurement Setup Measurement Procedure Measurement Examples...
Page 32
4338B ShortMeas Short Correction Complete Out Of Limit Figure 3-1. Connecting the DUT For More Information Measurement Examples...
Page 33
4338B Evaluating Battery Internal Resistance Measuring Battery Internal Resistance Requirements Measurement Setup If the internal resistance of the battery is higher than 10
, set the test level 100 A, not to be OVLD (overload). Measurement Procedure Measurement Examples...