Elektroanlage - rav KP5.337W Translation Of The Original Instructions

2 post lift
Table of Contents

Advertisement

11.
IMPIANTO ELETTRICO
Installazione da eseguire dall'utilizzatore
11. ELECTRICAL INSTALLATION
Power installations must be made by the user

11. ELEKTROANLAGE

Netzanschluss nur durch Elektrofachkräfte
1
0
FU
L1
L1
1
9
0
IG
2
10
23
FU1
17
TM1
U
3
MORSETTO
TR
TRASFORMATORE COMANDI 30 VA 0-230-400/0-27
TM1/2
TELERUTTORE COMANDO MOTORE 1/2
STM1/2 SONDA TERMICA MOTORE
M1/2
MOTORE COLONNA 1/2
IG
INVERTITORE GEN. DI FASE CON COMANDO SAL./DISC.
FU3
FUSIBILE PROTEZIONE SECONDARIO TR.5x20 3.15A 250V
RAPIDO
FU2
FUSIBILE PROTEZIONE PRIMARIO TR.5x20 1A 250V RAPIDO
(VERSIONE 230V) 10.3x38 1A 500V gl (VERSIONE 400V)
FU1
TERNA FUSIBILI PROTEZIONE LINEA MOTORI
230V 10.3x38 32A 400V AM (2x2,6KW) 14x51 40A 500V AM
(2x3,5KW)
400V 10.3x38 20A 500V AM (2x2,6KW) 10.3x38 25A 500V AM
(2x3,5KW)
FCS
FINECORSA DI SALITA
FCD1/2 FINECORSA DI DISCESA CARRELLO 1/2
FC2
FINECORSA CARRELLO 2 PIù ALTO DEL CARRELLO 1
FC1
FINECORSA CARRELLO 1 PIù ALTO DEL CARRELLO 2
RIFER. NOMENCLATURA
INSTALLAZIONE A CARICO DEL CLIENTE
V
HZ
230
50/60
32A aM
20A aM
FU
50/60
40A aM
25A aM
CAVO ALIMENTAZIONE 3P+TERRA x 4mmq VERS.400V
CAVO ALIMENTAZIONE 3P+TERRA x 6mmq VERS.230V
L2
L3
PE
nero 4mmq vers.400V
nero 6mmq vers.230V
L2
L3
11
13
15
17
16
12
14
18
24
25
nero 1.5mmq
14
400
230
18
19
13
FU2
giallo/verde 1mmq
TM2
V
W
Y
Z
X
M1
M2
3
11. INSTALLATION ÈLECTRIQUE
L'installation doit être effectée par l'usager
11. ESQUEMA ELECTRICO
La instalación tiene que efectuarla el utilizador
1
400
TIPO
1
2x2,6KW
2x3,5KW
STM2
2
STM1
3
FU3
FCS
4
4
27
8
0
0
8
IG
7
TR
6
FC1
7
7
TM1
8
rosso 1mmq
TERMINAL
COMMAND TRANSFORMER 30 VA 0-230-400/0-27
1/2 MOTOR COMMAND TELESWITCH
MOTOR HEAT PROBE
1/2 POST MOTOR
GEN. PHASE INVERTER WITH RISE/DESCENT COMMAND
SECONDARy PROTECTION FUSE TR.5x20 3.15A 250V
RAPID
PRIMARy PROTECTION FUSE TR 5x20 1A 250V RAPID
(230V VERSION) 10.3x381A 500V GL (VERSION 400V)
TRIPLET OF MOTOR LINE FUSES
230V 10.3x38 32A 400V AM (2x2,6KW) 14x51 40A 500V
AM (2x3,5KW)
400V 10.3x38 20A 500V AM (2x2,6KW) 10.3x38 25A
500V AM (2x3,5KW)
RISE LIMIT SWITCH
1/2 CARRIAGE DESCENT LIMIT SWITCH
LIMIT SWITCH TO BLOCK CARRIAGE 2 TO HIGHER
THAN CARRIAGE 1
LIMIT SWITCH TO BLOCK CARRIAGE 1 HIGHER THAN
CARRIAGE 2
DENOMINATIONS
0445-M004-3
3
3
rosso 1mmq
4
3
3
6
4
2
5
3
1
9
10
12
FC2
FC2
FC1
15
11
5
FCD1
FCD2
15
TM2
8
11
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp5.337lwKp5.337wkKp5.337lwkKp5.337wrKp5.337lwr

Table of Contents