11. Restore power to the unit by turning the power back ON
at the external main power switch.
12. Set both ON/OFF levers to ON to refill generator. When
full, add ½ to 1 gallon ( 1 to 1½ Gallons for the Model
24CGA10.2) of water through each descale port (to
remove foam from the water level controls)
13. Set both ON/OFF levers to OFF to drain the generators.
14. After the unit has drained completely, close the steamer
doors and set the ON/OFF levers/switches to the ON
position. The unit will fill with water.
15. Set the timers for 20-30 minutes and turn them on
(KEYPAD MODELS). The unit will come up to normal
operating temperature.
16. At the end of 20-30 minutes of cooking, turn OFF the
alarm (if necessary) and set the ON/OFF levers/switches
to the OFF position to drain the generators. Wait at least
5 minutes to ensure complete draining.
17. This is the final blowdown to rinse the unit. The steamer is now
ready for normal operation.
5. Yearly Maintenance
Clean Water Line Strainer
Clean the water line strainer at least once a year as follows:
NOTE: When the steamer is first installed, check the strainer more frequently to
find out how often it must be cleaned.
1. Close the valve(s) in the steamer water supply line(s).
2. Unscrew the filter cap from the bottom of the strainer. Refer
to Figure 3-1, which shows the various strainers supplied with
the different steamers.
3. On some models the strainers are built into the steamer and
are accessible from underneath the steamer (See Figure 3-
2), otherwise the strainers should be installed upstream of the
steamer in the water supply(s).
4. Remove the filter screen and wash it with clean water.
5. Check the O-ring for wear and replace it if necessary.
6. Put screen back into cap and replace the cap in the strainer.
7. Open water supply valve(s) and check for water
leaks.
B. OPERATIONAL CHARACTERISTICS BY MODEL
Model 24CGA6.2S and 24CGA10.2 are steamers designed for high capacity operation. The burners that
supply steam and the condenser spray to the compartments are on continuously while the unit is in timed
cooking mode or in the manual cooking mode. The burners and condenser spray stay on until the cooking
operation is complete, or until the idle timer automatically shuts OFF the steamer after the unit has
remained ON and idle for 60 minutes.
Model The STEAMSAVER
designed for high efficiency operation. These models incorporate the exclusive energy and water saving
24CGA6.2SES and The STEAMSAVER
COLD WATER SUPPLY LINES
model 24CGA10.2ES are steamers
37
MAIN EXTERNAL
POWER SWITCH
Gemini
DRAIN LINE
Figure 6-2 Main External
Power Switch
Fig. 3-1 Water Strainer Assembly
Fig. 3-2 Pre-installed Water Strainer
Assembly