Electrical connection

3
A
V06
Electrical connection
• Follow the installation instructions and the infor-
mation on the rating plate when connecting the
unit
• The units must be connected to a standard supply
line in conformity with your local regulations.
• Comply with all local regulations and standards!
• We recommend the use of an earth leakage
circuit breaker (30mA).
B
• On-site installation: provide accessible all-pole
disconnection device with a minimum of a 3 mm
contact gap.
• A permanent electrical connection must be
provided for the units.
The thermo cabinet (TC) will be delivered with a
power cord without plug. The connection box is
located on the bottom of the TC.
Connect the power cord in the following way:
PE (yellow/green wire)
N (blue wire)
L1 (brown wire)
Also there is a connection bolt for the earth con-
nection, located at the rear of the left front leg.
Connect the TC with a suitable cable to the earth
bonding system
- 14 -
pic 3 A
earth
neutral
phase
pic. 3 B