Shure Digital IntelliMix SCM820 Manual page 51

Automatic mixer
Hide thumbs Also See for Digital IntelliMix SCM820:
Table of Contents

Advertisement

Problem
No audio output for mixers
in a Link Group
Hardware
Problem
Can't make adjustments to the mixer
No LEDs are turning on
For additional Troubleshooting assistance or further information on complex installations, contact Shure to speak with a support
representative. In the Americas region, call Systems Support group at 847-600-8541. For users in other locations, go to
www.shure.com to find support contact for your region.
For digital audio networking help, advanced networking guidelines and Dante software troubleshooting, visit Audinate's website
at www.audinate.com.
Indicator
AutoMix Link LED
Indicator
lockout LED = Red
Power button = On
Red
Off
Green
Flashing Green
Off
Solution
Press and hold lockout button on the
back panel for 5 seconds to disable the
lockout.
If the mixer is still locked, open the web
application and uncheck the Hardware
Lockout button in the Preferences tab.
Uncheck No Lights Mode from the web
application Preferences tab
Shure Incorporated
Solution
Use Dante Controller soft-
ware (DC) to verify channel
subscriptions
Check master clock in DC
Use DC to properly route au-
dio channels
Turn up master gain control
Check Global/Local setting
for the Mix Outputs
Wait until the group has re-
configured
Ensure the mixer has been
assigned to a Link Group
from the Link Group tab of
the web application
51/59