Culligan Aquasential Cullar Owner's Manual page 9

Smart high efficiency water filters
Table of Contents

Advertisement

Culligan Smart HE Iron-Cleer Filters
Control Valve Type
Installation Environment
Overall Conditioner Height
Media Tank Dimensions (D x H)
Filter Media Type
Underbedding
G-50
Cullsan U
Capacity
1
Freeboard
2
Max� Clear Water (Soluble) Iron
Max� Hydrogen Sulfide
Minimum Alkalinity
pH for Iron Removal
Service Flow @ Pressure Drop (Clean Bed)
Normal
Maximum
4
Operating Pressure
Operating Temperature
Electrical Requirements (Control Valve)
Electrical Requirements (Compressor)
Drain Flow, Maximum
Regeneration Time
Backwash
Fast Rinse
1
Capacity based on 4 gpm and 10 mg/L of dissolved iron�
2
Measure from top of media bed to top of inlet fitting�
3
Hydrogen sulfide will be reduced significantly in water containing less than 5 ppm as tested by Culligan�
4
Max flow rates and pressure drop characteristics have not been validated by the Water Quality Association or IAPMO R&T�
The maximum specified flow rate at which the system will deliver treated water is defined as service flow�
* When compressor is running periodically, otherwise the power consumption is ~1 watt�
9
01040707 B 07/21
1" Reinforced Thermoplastic w/GBX
3
120VAC/60Hz, 175W/245W
10 gpm (5�5 gpm minimum required)
10" Iron-Cleer
Circuit Board
Indoor
67"
2 ea� 10" x 54"
1�0 cu� ft Birm
35 lb
25 lb
1400 gallons
21"
10 ppm
5�0 ppm
100 ppm
7�0 - 8�5
4 gpm @ 6 psi
6 gpm @ 9 psi
20-60 psi
33-120° F (1-48° C)
24VDC, 1W/60 Hz
(continuous/max)*
5–20 minutes
5–20 minutes
12" Iron-Cleer
1" Reinforced Thermoplastic w/GBX
Circuit Board
Indoor
65"
2 ea� 12" x 52"
1�5 cu� ft Birm
35 lb
25 lb
2000 gallons
18"
10 ppm
5�0 ppm
100 ppm
7�0 - 8�5
4 gpm @ 4 psi
9 gpm @ 14 psi
20-60 psi
33-120° F (1-48° C)
24VDC, 1W/60 Hz
120 Volts/60Hz, 175W/245W
(continuous/max)*
10 gpm (8�0 gpm minimum
required)
5–20 minutes
5–20 minutes