When the battery SOC is below the DischargeEndSOC@Grid value or
fully discharged, the inverter will stop working and
local loads will be supplied from the grid.
Thanks to the on-grid operation, the switch from battery power, PV power
and grid power is automatic and seamless.
iii.
When grid fails,
When grid fails, the inverter will automatically disconnect from grid and
output power to the EPS port.
When battery is discharged to the DischargeEndSOC@EPS value, the
inverter will stop working and wait for the grid to recover or until there is
sufficient power from PV panels to charge the battery.
If grid failure can be a common occurrence in your area, you can adjust
the DischargeEndSOC@Grid higher to ensure there is battery power
available.
iv. You can also:
Set a schedule for the inverter to charge the battery using cheap off-peak
grid power.
Specify the daily working periods of self-use for inverter.
*1: The inverter can be set not to feed power into the grid. But a small amount
of energy will still inevitably be fed into grid due to unpredictable PV energy
change and load fluctuations.
*2: Firmware update may be required to support this function.
For on-grid self-use operating mode, one can set the discharge end
SOC@Grid as low as the battery allows (10% or 20% for example).
Please refer to your local battery technician for minimum discharging
end SOC.
9

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hyper Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Hyper 2000Hyper 3000Hyper 3680Hyper 4600Hyper 5000

Table of Contents

Save PDF