Appendix
No.
Procedure
8
If the CO₂ is not within the tolerance:
9
After setting the CO₂, activate chimney
sweep mode again and measure the
CO₂ content
9
CO measurement (target value <
80 ppm)
10
Checking the condensate tray, siphon
and condensate discharge for leak-
tightness
11
Switching off the product and switching
it back on again
12
Programme the heating control with the
customer and check that the domestic
hot water/heating are working correctly
13
Stick sticker 835593 "Read the oper-
ating instructions" on the front of the
product, in the language spoken by the
end user
J
Technical data
Technical data – General
Designated country (des-
ignation in accordance
with ISO 3166)
Approved unit categories
Gas connection, boiler
side
Flow/return heating con-
nections, boiler side
Air/flue connection
Condensate discharge
pipe (min.)
G20 natural gas flow
pressure
G25 natural gas flow
pressure
G31 liquid gas flow pres-
sure
Gas flow rate at 15 °C
and 1013 mbar (G20)
Gas flow rate at 15 °C
and 1013 mbar (G25)
Gas flow rate at 15 °C
and 1013 mbar (G31)
Min. flue gas mass flow
rate (G20)
Max. flue gas mass flow
rate (G20)
Min. flue gas temperature
(at tV/tR = 80/60 °C)
Max. flue gas temperat-
ure (at tV/tR = 80/60 °C)
Approved gas-fired units
38
Comment
Adjust the CO₂ and then take the
measurement again
Target value for nominal heat input:
9.2 vol.% ±0.3 with natural gas H
Carry out a visual check or also use
CO analysers to go along the sealing
points.
End the chimney sweep mode
Handing over the operating instructions
to the customer
VKK 226/4-H
VKK 226/4-L
DE (Ger-
DE (Ger-
many),
many),
AT (Austria)
AT (Austria)
II
(DE),
II
(DE),
2ELL3P
2ELL3P
II
(AT)
II
(AT)
2H3P
2H3P
R 3/4 inch
R 3/4 inch
Rp1
Rp1
80/125 mm
80/125 mm
21 mm
21 mm
2 kPa
(20 mbar)
2.5 kPa
(25.0 mbar)
5 kPa
5 kPa
(50 mbar)
(50 mbar)
2.3 m³/h
2.7 m³/h
1.7 m³/h
1.7 m³/h
3.9 g/s
10.0 g/s
62 ℃
62 ℃
70 ℃
70 ℃
C13x, C33x,
C13x, C33x,
C43x, C53x,
C43x, C53x,
C83x, C93x,
C83x, C93x,
B23, B23P,
B23, B23P,
B33, B33P
B33, B33P
VKK 286/4-H
VKK 286/4-L
DE (Ger-
DE (Ger-
many),
many),
AT (Austria)
AT (Austria)
II
(DE),
II
(DE),
2ELL3P
2ELL3P
II
(AT)
II
(AT)
2H3P
2H3P
R 3/4 inch
R 3/4 inch
Rp1
Rp1
80/125 mm
80/125 mm
21 mm
21 mm
2 kPa
(20 mbar)
2.5 kPa
(25.0 mbar)
5 kPa
5 kPa
(50 mbar)
(50 mbar)
2.9 m³/h
3.3 m³/h
2.1 m³/h
2.1 m³/h
4.2 g/s
12.2 g/s
62 ℃
62 ℃
75 ℃
75 ℃
C13x, C33x,
C13x, C33x,
C43x, C53x,
C43x, C53x,
C83x, C93x,
C83x, C93x,
B23, B23P,
B23, B23P,
B33, B33P
B33, B33P
Installation and maintenance instructions ecoVIT exclusiv 0020258610_00
Required tool
CO₂ analyser
CO analyser
VKK 366/4-H
VKK 366/4-L
DE (Ger-
DE (Ger-
many),
many),
AT (Austria)
AT (Austria)
II
(DE),
II
(DE),
2ELL3P
2ELL3P
II
(AT)
II
(AT)
2H3P
2H3P
R 3/4 inch
R 3/4 inch
Rp1
Rp1
80/125 mm
80/125 mm
21 mm
21 mm
2 kPa
(20 mbar)
2.5 kPa
(25.0 mbar)
5 kPa
5 kPa
(50 mbar)
(50 mbar)
3.7 m³/h
4.3 m³/h
2.7 m³/h
2.7 m³/h
5.3 g/s
15.8 g/s
62 ℃
62 ℃
75 ℃
75 ℃
C13x, C33x,
C13x, C33x,
C43x, C53x,
C43x, C53x,
C83x, C93x,
C83x, C93x,
B23, B23P,
B23, B23P,
B33, B33P
B33, B33P