3

Technical data

Technical data – General
Designated country (des-
ignation in accordance
with ISO 3166)
Approved gas boiler cat-
egories
Gas connection, boiler
side
Flow/return heating con-
nections, boiler side
Domestic hot and cold
water connection, boiler
side
Expansion relief valve
connection pipe (min.)
Air/flue gas connection
Condensate drain pipe-
work (min.)
G20 natural gas flow
pressure
G31 propane gas flow
pressure
Gas flow rate at 15 °C
and 1013 mbar (based
on domestic hot water
generation, if applicable),
G20
Gas flow rate at 15 °C
and 1013 mbar (based
on domestic hot water
generation, if applicable),
G31
Min. flue gas mass flow
rate (G20)
Min. flue gas mass flow
rate (G31)
Max. flue gas mass flow
rate
Min. flue gas temperature
Max. flue gas temperat-
ure
Approved gas boiler
types
30% efficiency
NOx class
Test symbol/registration
no.
SAP 2009/2012 annual
efficiency (%)
Boiler dimension, width
Boiler dimension, height
Boiler dimension, depth
Mounting weight
8
VU 126/5-
VU 156/5-
5 (H-GB)
5 (H-GB)
ecoTEC plus
ecoTEC plus
612
615
GB (Great
GB (Great
Britain), IE
Britain), IE
(Ireland)
(Ireland)
I
I
2H
2H
15 mm
15 mm
22 mm
22 mm
15 mm
15 mm
60/100 mm
60/100 mm
19 mm
19 mm
2.0 kPa
2.0 kPa
(20.0 mbar)
(20.0 mbar)
1.3 m³/h
1.7 m³/h
1.44 g/s
1.44 g/s
5.6 g/s
7.0 g/s
40 ℃
40 ℃
70 ℃
70 ℃
C13, C33,
C13, C33,
C43, C53
C43, C53
109.3 %
109.3 %
6
6
CE‑
CE‑
0085CM0320
0085CM0320
89.3 %
89.2 %
440 mm
440 mm
720 mm
720 mm
338 mm
338 mm
36 kg
36 kg
VU 186/5-
VU 186/5-
5 (H-GB)
5 (P-GB)
ecoTEC plus
ecoTEC plus
618
618
GB (Great
GB (Great
Britain), IE
Britain), IE
(Ireland)
(Ireland)
II
II
2H3P
2H3P
15 mm
15 mm
22 mm
22 mm
15 mm
15 mm
60/100 mm
60/100 mm
19 mm
19 mm
2.0 kPa
(20.0 mbar)
3.7 kPa
(37.0 mbar)
2.0 m³/h
1.5 kg/h
1.80 g/s
2.40 g/s
8.4 g/s
8.4 g/s
40 ℃
40 ℃
70 ℃
70 ℃
C13, C33,
C13, C33,
C43, C53
C43, C53
109.6 %
108.5 %
6
6
CE‑
CE‑
0085CM0320
0085CM0320
89.6 %
89.6 %
440 mm
440 mm
720 mm
720 mm
338 mm
338 mm
36 kg
36 kg
Installation and maintenance instructions 0020244997_07
VU 246/5-
VU 306/5-
5 (H-GB)
5 (H-GB)
ecoTEC plus
ecoTEC plus
624
630
GB (Great
GB (Great
Britain), IE
Britain), IE
(Ireland)
(Ireland)
II
II
2H3P
2H3P
15 mm
15 mm
22 mm
22 mm
15 mm
15 mm
60/100 mm
60/100 mm
19 mm
19 mm
2.0 kPa
2.0 kPa
(20.0 mbar)
(20.0 mbar)
2.6 m³/h
3.7 m³/h
2.47 g/s
2.78 g/s
11.1 g/s
13.9 g/s
40 ℃
40 ℃
70 ℃
70 ℃
C13, C33,
C13, C33,
C43, C53
C43, C53
109.5 %
109.4 %
6
6
CE‑
CE‑
0085CM0320
0085CM0320
89.6 %
89.5 %
440 mm
440 mm
720 mm
720 mm
338 mm
372 mm
37 kg
38 kg