Technical data – Power/load (G31)
Nominal heat output
range P at 80/60 °C
Nominal heat output
range P at 60/40 °C
Nominal heat output
range P at 50/30 °C
Nominal heat output
range P at 40/30 °C
Maximum heat input,
heating side
Minimum heat input
Nominal heat output
range P at 80/60 °C
Nominal heat output
range P at 60/40 °C
Nominal heat output
range P at 50/30 °C
Nominal heat output
range P at 40/30 °C
Maximum heat input,
heating side
Minimum heat input
Technical data – Heating
Max. flow temperature
adjustment range (default
setting: 75 °C)
Permissible total over-
pressure
Floor-standing boiler ca-
pacity
Circulation water volume
(with reference to
ΔT= 20 K)
Pressure loss (with refer-
ence to ΔT= 20 K)
Condensate volume at
heating mode 40/30 °C
Heating standby losses
per day (heating 70 °C)
Max. flow temperature
adjustment range (default
setting: 75 °C)
Permissible total over-
pressure
Floor-standing boiler ca-
pacity
Circulation water volume
(with reference to
ΔT= 20 K)
Pressure loss (with refer-
ence to ΔT= 20 K)
0020258610_00 ecoVIT exclusiv Installation and maintenance instructions
VKK 226/4-H
VKK 226/4-L
9.6
9.6
... 21.3 kW
... 21.3 kW
10.1
10.1
... 22.4 kW
... 22.4 kW
10.3
10.3
... 22.9 kW
... 22.9 kW
10.6
10.6
... 23.5 kW
... 23.5 kW
22.0 kW
22.0 kW
9.9 kW
9.9 kW
VKK 476/4-H
VKK 476/4-L
19.6
19.6
... 43.6 kW
... 43.6 kW
20.6
20.6
... 46.0 kW
... 46.0 kW
21.0
21.0
... 46.8 kW
... 46.8 kW
21.6
21.6
... 48.2 kW
... 48.2 kW
45.0 kW
45.0 kW
20.2 kW
20.2 kW
VKK 226/4-H
VKK 226/4-L
40 ... 85 ℃
40 ... 85 ℃
0.3 MPa
0.3 MPa
(3.0 bar)
(3.0 bar)
100 l
100 l
860 l/h
860 l/h
0.00035 MPa
0.00035 MPa
(0.00350 bar)
(0.00350 bar)
2.2 l/h
2.2 l/h
3.4 kWh
3.4 kWh
VKK 476/4-H
VKK 476/4-L
40 ... 85 ℃
40 ... 85 ℃
0.3 MPa
0.3 MPa
(3.0 bar)
(3.0 bar)
85 l
85 l
1,935 l/h
1,935 l/h
0.0017 MPa
0.0017 MPa
(0.0170 bar)
(0.0170 bar)
VKK 286/4-H
VKK 286/4-L
13.1
13.1
... 26.2 kW
... 26.2 kW
13.8
13.8
... 27.5 kW
... 27.5 kW
14.0
14.0
... 28.1 kW
... 28.1 kW
14.4
14.4
... 28.9 kW
... 28.9 kW
27.0 kW
27.0 kW
13.5 kW
13.5 kW
VKK 656/4-H
VKK 656/4-L
21.1
21.1
... 60.1 kW
... 60.1 kW
22.1
22.1
... 63.2 kW
... 63.2 kW
22.6
22.6
... 64.5 kW
... 64.5 kW
23.2
23.2
... 66.3 kW
... 66.3 kW
62.0 kW
62.0 kW
21.7 kW
21.7 kW
VKK 286/4-H
VKK 286/4-L
40 ... 85 ℃
40 ... 85 ℃
0.3 MPa
0.3 MPa
(3.0 bar)
(3.0 bar)
100 l
100 l
1,160 l/h
1,160 l/h
0.0006 MPa
0.0006 MPa
(0.0060 bar)
(0.0060 bar)
3.0 l/h
3.0 l/h
3.4 kWh
3.4 kWh
VKK 656/4-H
VKK 656/4-L
40 ... 85 ℃
40 ... 85 ℃
0.3 MPa
0.3 MPa
(3.0 bar)
(3.0 bar)
85 l
85 l
2,650 l/h
2,650 l/h
0.0043 MPa
0.0043 MPa
(0.0430 bar)
(0.0430 bar)
Appendix
VKK 366/4-H
VKK 366/4-L
15.2
15.2
... 34.0 kW
... 34.0 kW
16.0
16.0
... 35.7 kW
... 35.7 kW
16.3
16.3
... 36.4 kW
... 36.4 kW
16.8
16.8
... 37.5 kW
... 37.5 kW
35.0 kW
35.0 kW
15.7 kW
15.7 kW
VKK 366/4-H
VKK 366/4-L
40 ... 85 ℃
40 ... 85 ℃
0.3 MPa
0.3 MPa
(3.0 bar)
(3.0 bar)
89 l
89 l
1,505 l/h
1,505 l/h
0.0010 MPa
0.0010 MPa
(0.0100 bar)
(0.0100 bar)
3.5 l/h
3.5 l/h
3.4 kWh
3.4 kWh
41