D Maintenance Plan; E Technical Data - Vaillant eloSTOR pro VEH 50/7-3 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Operating mode
Mains connection
Manual mode
1 2
1 2
D
Maintenance plan
Maintenance work
Checking seals
Tighten the fixing screws
Checking the magnesium protection anode
Checking the inner vessel and components for scale deposition
E
Technical data
Technical data – General
Operating mode
Thermal insulation
Inner vessel
Safety
Technical data – General
Product dimensions, height
Product dimensions, width
Product dimensions, depth
Weight when filled with water
Nominal capacity
Electrical power consumption
Technical data – Output
Standby energy consumption (in 24 hours at
65 °C)
Selectable hot water temperature range
Energy-saving setting
Mixed water volume from 40 °C
0020196671_06 eloSTOR pro Installation and maintenance instructions
L1
L2
N
PE
4 5
L1
L2
L3
N
L1
L2
L3
N
PE
4 5
L1
L2
L3
N
VEH 7-3
Single- or twin-circuit switching or manual operation
PU foam, CFC-free
Steel, enamelled, with magnesium protection anode
Complies with national safety regulations; radio-shielded; does not affect the mains
supply
VEH 50/7-3
637 mm
504 mm
450 mm
80 kg
50 l
– 1 kW
– 2 kW
– 4 kW
– 6 kW
VEH 50/7-3
0.6 kWh
7 ... 85 °C
60 °C
96 l
Basic load
Rapid heating
4 kW
4.5 kW
6 kW
6 kW
VEH 80/7-3
VEH 100/7-3
875 mm
1.041 mm
504 mm
504 mm
450 mm
450 mm
130 kg
160 kg
80 l
100 l
– 1 kW
– 1 kW
– 2 kW
– 2 kW
– 4 kW
– 4 kW
– 6 kW
– 6 kW
VEH 80/7-3
VEH 100/7-3
0.8 kWh
0.93 kWh
7 ... 85 °C
7 ... 85 °C
60 °C
60 °C
157 l
196 l
Appendix
VEH 50/7-3
VEH 80/7-3
VEH 100/7-3
VEH 120/7-3
VEH 50/7-3
VEH 80/7-3
VEH 100/7-3
VEH 120/7-3
Interval
Each time maintenance work is
carried out
Each time maintenance work is
carried out
Every three years
Every three years
VEH 120/7-3
1.207 mm
504 mm
450 mm
185 kg
120 l
– 1.5 kW
– 3 kW
– 4.5 kW
– 6 kW
VEH 120/7-3
1.06 kWh
7 ... 85 °C
60 °C
237 l
15