C
Overview of diagnostics codes
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Code
Parameter
D.000
Heating partial load
D.001
Pump overrun: Heating
D.002
Max. anti-cycl. time: Heat-
ing
D.004
Cylinder temperature ac-
tual value
D.005
Heating target flow temper-
ature
D.007
Cylinder temperature tar-
get value
D.008
Controller 3-4
D.009
eBUS controller target
value
D.010
Internal pump
D.011
External pump
D.012
Cyl. charging pump
D.013
Circulation pump
0020258610_00 ecoVIT exclusiv Installation and maintenance instructions
Values
Unit
Explanation, selection, increment
Min.
Max.
Output-range-
kW
Adjustable partial heat load
specific
Maximum value = automatic partial
heat load
Product automatically adjusts the
max. partial load to the current
system demand
2
60
min
Overrun time of internal heating
pump for heating mode
1
2
60
min
Max. burner anti-cycling time heat-
ing at 20 °C flow temperature
1
Current value
Measured value for the domestic
hot water sensor if a domestic hot
water cylinder with sensor is con-
nected
Current value
Flow temperature target value (or
return target value)
Current target value, calculated
from the set value, control, control
type, etc.
Current value
Only products with no integrated
hot water generation and with a
connected cylinder
15 °C = frost protection, 40 °C up
to D.020 (max. 70 °C)
Current value
Room thermostat at terminal 3-4
0: RT input terminals 3-4 interrup-
ted, no heating mode
1: RT input terminals 3-4 closed,
no heating mode
Current value
Target flow temperature from the
external eBus control
Minimum from the external eBUS
target value and the target value
for terminal 7
Current value
Heating pump status
0: Off
1: On
Current value
Status of additional external heat-
ing pump
0: Off
1-100: On
Connection via 2 in 7 multi-func-
tional module or X6
Current value
Status of cylinder charging pump
0: Off
1-100: On
Current value
Status of circulation pump
0: Off
1-100: On
Connection via 2 in 7 multi-func-
tional module or X6
Appendix
Default
Own
setting
setting
Maximum
value
5
20
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
27