Vaillant ecoVIT exclusiv Installation And Maintenance Instructions Manual page 29

Table of Contents

Advertisement

Code
Parameter
D.040
Flow temperature actual
value
D.041
Return temperature actual
value
D.043
Boiler temperature
D.044
Ionisation value actual
value
D.047
Current outside temperat-
ure
D.050
Offset min. speed
D.051
Offset max. speed
D.054
Switch-on hysteresis offset
D.055
Switch-off hysteresis off-
set
D.060
Number of safety therm.
shut-downs
D.061
No. of shut-downs in ign.
flame controller
D.063
Air-monitoring switch-off
sequences
D.064
Avg. ignition time
D.065
Max. ignition time
D.067
Remaining anti-cycl. time
for heating
D.068
Number of first start at-
tempts
D.069
Number of second start
attempts
D.071
Max. heating target flow
temp.
D.072
Pump overrun after cylin-
der charging
D.073
Offset setting for comfort
mode
D.075
Max. cylinder charging
time
D.076
Device Specific Number
D.077
DHW partial load
0020258610_00 ecoVIT exclusiv Installation and maintenance instructions
Values
Unit
Explanation, selection, increment
Min.
Max.
Current value
Current value
0
99
Current boiler temperature
0
1020
> 700: No flame
< 450: Flame detected
< 250: Excellent flame
Current value
If an outdoor temperature sensor is
connected to X41
(with Vaillant weather-compensated
control)
-40
40
rpm
Nominal value set in factory
10
-40
40
rpm
Nominal value set in factory
10
0
-10
1
0
10
1
Current value
Number of safety cut-out switch-off
sequences
Current value
Number of unsuccessful ignitions in
the last attempt
Current value
Current value
s
Current value
s
Current value
min
Remaining burner anti-cycling time
Current value
Number of unsuccessful ignitions at
1st attempt
Current value
Number of unsuccessful ignitions at
2nd attempt
40
85
Target value maximum heating flow
temperature
1
0
600
s
External heating pump overrun
time after cylinder charging
1
0
25
Cylinder charging offset
Excess temperature between the
target cylinder temperature and
the target flow temperature when
cylinder charging
1
20
90
min
Max. charging time for domestic
hot water cylinder without inde-
pendent control system
1
Current value
(Device specific number = DSN)
15: ecoVIT
Output-range-
kW
Adjustable cylinder charging output
specific
Number of switch-off sequences
caused by the air monitoring
Maximum value = automatic
cylinder partial load
Appendix
Default
Own
setting
setting
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
-2
6
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
75
300
25
45
Not ad-
justable
Maximum
value
29