Code
Parameter
D.040
Flow temperature actual
value
D.041
Return temperature actual
value
D.043
Boiler temperature
D.044
Ionisation value actual
value
D.047
Current outside temperat-
ure
D.050
Offset min. speed
D.051
Offset max. speed
D.054
Switch-on hysteresis offset
D.055
Switch-off hysteresis off-
set
D.060
Number of safety therm.
shut-downs
D.061
No. of shut-downs in ign.
flame controller
D.063
Air-monitoring switch-off
sequences
D.064
Avg. ignition time
D.065
Max. ignition time
D.067
Remaining anti-cycl. time
for heating
D.068
Number of first start at-
tempts
D.069
Number of second start
attempts
D.071
Max. heating target flow
temp.
D.072
Pump overrun after cylin-
der charging
D.073
Offset setting for comfort
mode
D.075
Max. cylinder charging
time
D.076
Device Specific Number
D.077
DHW partial load
0020258610_00 ecoVIT exclusiv Installation and maintenance instructions
Values
Unit
Explanation, selection, increment
Min.
Max.
℃
–
Current value
℃
–
Current value
℃
0
99
Current boiler temperature
–
0
1020
> 700: No flame
< 450: Flame detected
< 250: Excellent flame
℃
Current value
If an outdoor temperature sensor is
connected to X41
(with Vaillant weather-compensated
control)
-40
40
rpm
Nominal value set in factory
10
-40
40
rpm
Nominal value set in factory
10
K
0
-10
1
K
0
10
1
–
Current value
Number of safety cut-out switch-off
sequences
–
Current value
Number of unsuccessful ignitions in
the last attempt
–
Current value
–
Current value
s
–
Current value
s
Current value
min
Remaining burner anti-cycling time
–
Current value
Number of unsuccessful ignitions at
1st attempt
–
Current value
Number of unsuccessful ignitions at
2nd attempt
℃
40
85
Target value maximum heating flow
temperature
1
0
600
s
External heating pump overrun
time after cylinder charging
1
K
0
25
Cylinder charging offset
Excess temperature between the
target cylinder temperature and
the target flow temperature when
cylinder charging
1
20
90
min
Max. charging time for domestic
hot water cylinder without inde-
pendent control system
1
–
Current value
(Device specific number = DSN)
15: ecoVIT
Output-range-
kW
Adjustable cylinder charging output
specific
Number of switch-off sequences
caused by the air monitoring
Maximum value = automatic
cylinder partial load
Appendix
Default
Own
setting
setting
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
–
-2
6
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
75
300
25
45
–
Not ad-
justable
Maximum
value
29