Lantech IGC-0101DSFP User Manual

Lantech IGC-0101DSFP User Manual

10/100/1000t (poe at) to 100/1000m sfp industrial switch converter

Advertisement

Quick Links

Lantech
IGC-0101DSFP
IPGC-0101DSFP
10/100/1000T (PoE at) to 100/1000M
SFP Industrial Switch Converter
User Manual
Oct 2020

Advertisement

Table of Contents
loading

Summary of Contents for Lantech IGC-0101DSFP

  • Page 1 Lantech IGC-0101DSFP IPGC-0101DSFP 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter User Manual Oct 2020...
  • Page 2 Recommendation for Shielded network cables STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable.
  • Page 3: Table Of Contents

    Content Overview ............1 Introduction: IGC-0101DSFP ........1 Introduction: IPGC-0101DSFP ........ 2 Packing List ............3 Safety Precaution ........... 3 Hardware Description ......... 4 Front Panel ............. 4 Top View ..............5 Wiring the Power Inputs .......... 5 Wiring the Fault Alarm Contact ....... 6 LED Indicators ............
  • Page 4 Rack-mounting ............. 16 Hardware Installation ........18 Installation Steps ..........18 Troubles shooting ..........20...
  • Page 5 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy.
  • Page 6: Overview

    Overview Introduction: IGC-0101DSFP The Lantech IGC-0101DSFP is an Industrial Converter converting from 10/100/1000BaseT to 100/1000M-FX dual speed. It supports 10K bytes jumbo frame. Auto-sensing LLF and Power Fault LED/relay alarm setting by DIP switch Featured with LLF (Link Loss Forwarding) function, Lantech IPGC-0101DSFP is able to auto cut off connection if one end of connection is down.
  • Page 7: Introduction: Ipgc-0101Dsfp

    Introduction: IPGC-0101DSFP The Lantech IPGC-0101DSFP is an Industrial Converter converging from 10/100/1000BaseT to 100/1000M-FX dual speed with 802.3at/af PoE support. It supports 10K jumbo frame. Auto-sensing LLF and Power Fault LED/relay alarm setting by DIP switch Featured with LLF (Link Loss Forwarding) function, Lantech IPGC-0101DSFP is able to auto cut off connection if one end of connection is down.
  • Page 8: Packing List

    Packing List  1 x 10/100/1000 to Mini-GBIC Industrial Switch Converter  1 x Terminal Block Safety Precaution Attention IF DC voltage is supplied by an external circuit, please use a protection device on the power supply input.
  • Page 9: Hardware Description

    Hardware Description In this paragraph, we will introduce the Industrial switch converter’s hardware spec, port, cabling information, and wiring installation. Front Panel The Front Panel of the IGC-0101DSFP/IPGC-0101DSFP is shown as below. Front Panel of the Industrial Switch Converter...
  • Page 10: Top View

    Top View The top panel of the Industrial Switch Converter is equipped one terminal block connector of two DC power inputs. Top panel of the Industrial Switch Converter Wiring the Power Inputs Please follow the steps below to insert the power wire. 1.
  • Page 11: Wiring The Fault Alarm Contact

    2. To tighten the wire-clamp screws for preventing the DC wires to loose. Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below. Inserting the wires, it will detect the fault status which the power is failure or port link failure (for managed model) and form an open circuit.
  • Page 12: Led Indicators

    LED Indicators There are few LEDs display the power status and network status located on the front panel of the Industrial switch converter, each of them has its own specific meaning as below table. Table 2.1: Industrial Switch Converter LED Definition Color Description Power input 1 is active...
  • Page 13: Ports

    Ports RJ-45 ports (Auto MDI/MDIX): The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX or 1000Base-T devices connections. Auto MDI/MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling. See figures as below for straight through and crossover cable schematic. ...
  • Page 14: Cabling

    Straight Through Cable Schematic Cross Over Cable Schematic Cabling Twisted-pair segment can use unshielded twisted pair (UTP) or shielded twisted pair (STP) cabling. The cable between the link partner (switch, hub, workstation, etc.) and the converter must be less than 100 meters (328 ft.) long and comply with the IEEE 802.3ab 1000Base-T standard for Category 5e or above.
  • Page 15 Figure 2.8: Transceiver to the SFP module Figure 2.9: Transceiver Inserted...
  • Page 16 Second, insert the fiber cable of LC connector into the transceiver. Figure 2.10: LC connector to the transceiver To remove the LC connector from the transceiver, please follow the steps shown below: First, press the upper side of the LC connector from the transceiver and pull it out to release.
  • Page 17 Second, push down the metal loop and pull the transceiver out by the plastic part. Figure 2.12: Pull out from the SFP module...
  • Page 18: Mounting Installation

    Mounting Installation DIN-Rail Mounting The DIN-Rail is screwed on the industrial switch when out of factory. If the DIN-Rail is not screwed on the industrial switch, please see the following figure to screw the DIN-Rail on the switch. Follow the below steps to hang the industrial switch.
  • Page 19 First, insert the top of DIN-Rail into the track. Then, lightly push the button of DIN-Rail into the track. Check the DIN-Rail is tightly on the track. To remove the industrial switch from the track, reverse steps above.
  • Page 20: Wall Mount Plate Mounting

    Wall Mount Plate Mounting *Optional Wall Mount Kit required Follow the steps below to mount the industrial switch with the wall mount plates included. 1. To remove the DIN-Rail clip from the industrial switch, unscrew the screws to remove the DIN-Rail clip. 2.
  • Page 21: Rack-Mounting

    Rack-mounting *Optional 19-inch Rack Mounting Kit & L-Bracket are required When installing the converter in a 19 inch rack, this procedure requires the following items:  One 19-inch rack mounting kit (optional)  One set (two pieces) L-bracket (optional) for one converter ...
  • Page 22 Have another person hold the whole kit in the equipment rack while you secure it using standard rack mount screws (not provided).
  • Page 23: Hardware Installation

    Hardware Installation In this paragraph, we will describe how to install the 10/100/1000Base-T Industrial Switch converter and the installation points for the attention. Installation Steps Unpacked the Industrial switch converter packing. Check the DIN-Rail is screwed on the Industrial switch converter. If the DIN-Rail is not screwed on the Industrial switch converter.
  • Page 24 Industrial switch converter will light up. Please refer to the LED Indicators section for meaning of LED lights. Prepare the twisted-pair, straight through Category 5 cable for Ethernet connection. Insert one side of Category 5e or above cables into the Industrial switch converter Ethernet port (RJ-45 port) and another side of category 5e or above cables to the network devices’...
  • Page 25: Troubles Shooting

    Troubles shooting  Verify that you are using the right power cord/adapter, please don’t use the power adapter with output higher than product spec, or it will burn this switch converter down.  Select the proper UTP cable to construct your network. Please check that you are using the right cable.