Lantech IPGS-5400-2P User Manual

Lantech IPGS-5400-2P User Manual

4 modular slots industrial l2+ managed (poe) switch w/itu, g.8032 ring

Advertisement

Quick Links

IPGS-5400-2P
IGS-5400-2P
4 Modular Slots Industrial L2+ Managed (PoE) Switch w/ITU
G.8032 Ring
User Manual (Hardware)
May. 2016

Advertisement

Table of Contents
loading

Summary of Contents for Lantech IPGS-5400-2P

  • Page 1 IPGS-5400-2P IGS-5400-2P 4 Modular Slots Industrial L2+ Managed (PoE) Switch w/ITU G.8032 Ring User Manual (Hardware) May. 2016...
  • Page 2 Recommendation for Shielded network cables STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable.
  • Page 3 Lantech Communications Global Inc. Products offered may contain software which is proprietary to Lantech Communications Global Inc. The offer or supply of these products and services does not include or infer any transfer of ownership.
  • Page 4 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy.
  • Page 5: Table Of Contents

    Content Chapter 1 Introduction ..........5 Specification ............. 5 Chapter 2 Hardware Description ......8 Physical Dimension ........8 IP Protection ........... 9 LED Indicators..........12 Chapter 3 Hardware Installation ......13 Hardware installation ..........13 Rack Mounting ..........14 Wiring the Power Inputs .......
  • Page 6: Chapter 1 Introduction

    Chapter 1 Introduction Lantech IPGS/IGS-5400-2P is a high performance L2 + managed industrial switch which provides L2 wire speed and advanced security function for network aggregation and backbone deployment. Specification IEEE IEEE 802.3 10Base-T Ethernet Standards IEEE 802.3u 100Base-TX Ethernet IEEE 802.3ab 1000Base-TX Ethernet...
  • Page 7 Per unit: Power 1 (Green), Power 2 (Green), Alarm (Red) ,R.M (Green) Link/Activity (Green), Full duplex/collision(Yellow)), MINI GBIC (Link/Activity )(Green) Power Supply IGS-5400-2P: 1 built-in power + 1 optional power IPGS-5400-2P: 1 built-in power + 1 optional power + 1 PoE power  VAC/VDC isolated 4000V 85V~265VAC/100~370VDC ...
  • Page 8 DI/DO 2 Digital Input (DI) : Level 0: -30~2V / Level 1: 10~30V Max. input current:8mA 2 Digital Output(DO): Open collector to 40 VDC, 200mA 19” Metal case,IP-30; 440mm(W)x325mm(D)x44mm(H) Case Dimension Operating 5%~95% (Non-condensing) Humidity Operating -20°C ~60°C Temperature Storage -40°C ~85°C Temperature FCC Class A, CE EN61000-4-2 (ESD),...
  • Page 9: Chapter 2 Hardware Description

    Chapter 2 Hardware Description In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation. 2.1 Physical Dimension Metal case. IP-30, 440(W) x 325 (D) x 44 (H) mm...
  • Page 10: Ip Protection

    2.2 IP Protection The IP Code, Ingress Protection Rating, sometimes also interpreted as International Protection Rating, classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water in mechanical casings and with electrical enclosures. It is published by the International Electrotechnical Commission (IEC) Solid particle protection The first digit indicates the level of protection that the enclosure provides against access...
  • Page 11 Liquid ingress protection The second digit indicates the level of protection that the enclosure provides against harmful ingress of water. Protected Level Testing for Details against — — protected Dripping Dripping water (vertically Test duration: 10 minutes water falling drops) shall have no Water equivalent to 1 mm harmful effect.
  • Page 12 water jets jets (12.5 mm nozzle) 3 minutes against the enclosure from Water volume: 100 litres per any direction shall have no minute harmful effects. Pressure: 100 kPa at distance of 3 m Immersion Ingress of water in harmful Test duration: 30 minutes up to 1 m quantity shall not be Immersion at depth of at...
  • Page 13: Led Indicators

    2.3 LED Indicators The diagnostic LEDs that provide real-time information of system and optional status are located on the front panel of the industrial switch. The following table provides the description of the LED status and their meanings for the switch. Color Status Meaning...
  • Page 14: Chapter 3 Hardware Installation

    Chapter 3 Hardware Installation Hardware installation 1. Unpack the Industrial switch 2. Check if the Rack mount brackets are screwed on the Industrial switch or not. If the Rack mount brackets are not screwed on the Industrial switch, please refer to Rack Mounting section for rack installation.
  • Page 15: Rack Mounting

    3.1 Rack Mounting When installing the IPGS/IGS-5424 switch in a 19 inch rack, it must always be mounted horizontally with the top side up, This procedure requires the following items: ■ Eight bracket screws (included with the switch) ■ Two equipment rack brackets (included with the switch) ■...
  • Page 17: Wiring The Power Inputs

    Please follow the steps below to insert the power wire. Note:  The input power of PoE of IPGS-5400-2P(power input 3) is separated with power of switch system(power input 1 and 2).  The power input module 2 is an optional part.
  • Page 18 1. For the power module EOTH000701, install the power module then insert DC or AC power wires into the contacts V+ and V– of power module. For the power module EOTH000702, install the power module then insert DC power wires into the contacts V+ and V– of power module. 3.
  • Page 19 6. Insert DC power wires into the contacts + and - for power 3 for PoE .(Only for IPGS- 5400-2P) 7. Tighten the wire-clamp screws for preventing the wires from loosing. [NOTE] The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG.
  • Page 20: Wiring The Fault Alarm Contact

    3.3 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the switch will detect the fault status of the power failure, or port link failure (available for managed model) and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
  • Page 21: Cabling

    3.4 Cabling  Use four twisted-pair, Category 5e or above cabling for RJ-45 port connection. The cable between the switch and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.  Fiber segment using single-mode connector type must use9/125 µm single-mode fiber cable.
  • Page 22 Transceiver Inserted Second, insert the fiber cable of LC connector into the transceiver. LC connector to the transceiver...
  • Page 23 To remove the LC connector from the transceiver, please follow the steps shown below: First, press the upper side of the LC connector to release from the transceiver and pull it out. Remove LC connector Second, push down the metal loop and pull the transceiver out by the plastic handle. Pull out from the transceiver...
  • Page 24: Usb Dongle

    3.5 USB Dongle The USB slot is to backup and restore the setting of switch automatically by any USB dongle. It doesn’t need any configuration from web browser or other user interface. When you plug USB dongle in switch , the switch will backup its configuration file automatically, the backup file will be named cfgexport_(switch MAC).yml, if you want to restore the backup file , just rename the configuration file as cfgimport_(switch MAC).yml then plug the USB dongle again.
  • Page 25: Chapter 4 Network Application

    Chapter 4 Network Application ITU G.8032 Scheme Lantech G.8032 protocol is following ITU (International Telecommunication Unit) G.8032 v2 draft. The benefits of G.8032 are: 1. <50ms recovery time when failover 2. G.8032 has defined the protocol scheme, parameters, functions, test measures to be unified that the users can evaluate the possible network infrastructure without literally testing each brand in large scale.
  • Page 26: Multiple Rings

    Multiple Rings...
  • Page 27: Dual Homing

    Dual Homing Chain...
  • Page 29: Chapter 5 Console Management

    Chapter 5 Console Management 5.1 Connecting to the Console Port The supplied RS-232 cable which one end is DB9 female connector and the other end is DB9 male connector. Attach the end of DB9 female connector to PC or terminal and the other end of DB9 male connector to the console port of the switch.
  • Page 30: Login In The Console Interface

    5.2 Login in the Console Interface When the connection between Switch and PC is ready, turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication parameters to match the following default characteristics of the console port: Baud Rate:115200 bps Data Bits: 8 Parity: none...
  • Page 31 Console login interface ===============Notice=============== For web-based management, please refer to our “Software Management Manual” at http://www.lantechcom.tw/global/eng/support-downloads.html...