PROGRAMMING MENU

Icon
Sets the HOURS and DAY. Press the PROG
button (2) again to enter the sub-menu and
proceed to set the parameter. The hours
and day are automatically set if WiFi Box is
connected to an internet network. From the
APP it is possible to synchronize the hours and
the day of the thermostat with your Tablet or
Smartphone time.
Sets the temperature of DOMESTIC HOT
WATER (when OTBus connection available
between WiFi Box and the boiler). Press
DHW
the PROG button (2) again to enter the sub-
menu and proceed to set the parameter.
Reads SENSORS/BOILER SETTINGS
(when OTBus connection available between
WiFi Box and the boiler and if the OTBus
InFO
allows it). Press the PROG button (2) again
to enter the sub-menu and proceed to read
the values available.
Description
With the
(3) and
(1) buttons select the desired
value (hours, minutes or days) and with the
(10) buttons select the values. Press the PROG
button (2) to enter and return to the programming menu,
press MODE button (9) to escape from the programming
menu or wait 5 seconds to auto exit.
With the
(8) and
temperature value. Press the PROG button (2) to enter
and return to the programming menu, press MODE
button (9) to enter and exit from the programming menu
or wait 5 seconds to auto exit.
Below, are the parameters of the info in sequence (if the
value is not available "- -" is shown):
tSEt = set-point supply temperature calculated by the
thermostat.
tFLO = reading of the boiler supply sensor temperature.
trEt = reading of the boiler return sensor temperature.
tdH = reading of the boiler DHW sensor temperature.
tFLU = reading of the boiler flue sensor temperature.
tESt = reading of the boiler outdoor sensor temperature
(fitted to the boiler or communicated by the web).
MOdU = instantaneous percentage of modulation of boiler
fan.
FLOr = instantaneous domestic hot water flow rate.
HOUr = hours worked in high condensation mode.
PrES = central heating system pressure.
tFL2 = reading of the heating supply sensor on second
circuit
9
or
select the desired icon
Sub-menu
(8) and
(10) buttons select the desired