Riello RiCLOUD NA Series Quick Start Manual page 14

Table of Contents

Advertisement

ONLY QUALIFIED PERSONEL
TECHNICAL MENU AND EXPERTISE SETTINGS
Parameter
Description
Icon
Set the minimum limit temperature
01 t0
(frost protection for ON/OFF and DHW/
SUMMER mode).
Set max and minimum set point in
08 HH/LL
heating.
CH
Available only when OTBus is
connected.
Set the climatic curve for
thermoregulation.
10 CLI
Available only when OTBus is
connected.
Set the influence of the room sensor on
11 InFL
thermoregulation calculation. Available
only when OTBus is connected.
13 CALI
Calibration of the room sensor.
Factory values RESET (general
14 FACt
RESET).
16 SOFt
Software version of the thermostat.
17 dEGr
Set degree in Celsius or Fahrenheit.
19 H
Set hysteresis On and OFF.
On/OFF
Alarm history. Available only when
21 ALL
OTBus is connected.
Boiler parameter settings (TSP).
22 tSP
Available only when OTBus is
connected.
Legionella function activation.
23 LEGI
Available only when OTBus is
connected.
Domestic hot water clock activation.
24 CLOC
Available only when OTBus is
connected.
Night swift flow temperature reduction.
26 tSFt
Available only when OTBus is
connected.
Temperature sensor disability (for pure
27 SEnS
climatic curve activation when in OT).
Set clock display 24hr or 12 hr (am,
28 FCLO
pm).
Disable the OT CH request when
29 CHOt
OTBus is connected.