Sets the desired room temperature levels:
T1 - T2 - T3.
Press the PROG button (2) to enter the sub-
menu and proceed to set the parameter. The 3
values can be changed individually with the
(8) and
(10) buttons when the respective 'T'
value is active on the thermostat.
Sets the PROGRAMMING HEATING/
COOLING TIME. Press the PROG button (2) to
enter the sub-menu and proceed to set. With
(3) and
(1) buttons select the period (mon-fri,
sat-sun, single day). Press again the PROG
button (2) to enter the sub-menu and proceed
to set.
Sets the HEATING or COOLING mode.
Press the PROG button (2) again to enter the
sub-menu and proceed to set the parameter.
Note: In the cooling mode, if the OTbus
connection is established between the WIFI
box and the boiler, the cooling request is
managed only via ON/OFF (heating is disabled
vs the boiler).
Technical menu (available only to service
personnel).
Press the PROG button (2) button again to
enter the sub-menu and proceed to set the
parameters.
Press the PROG button (2) to exit from the programming menu.
Description
With
(3) and
(1) buttons select the desired value
(T1, T2 or T3) and with the
select the values. Press the PROG button (2) to enter
and return to the programming menu, press the MODE
button (9) to enter and exit from the programming menu
or wait 5 seconds to auto exit.
With
(3) and
(1) buttons select the segment of hours
that need to be modified and with the MODE button (9)
select the desired temperature value level (T1, T2, T3).
Press the
(8) button to copy the previous setting (use
the
(10) button to go back). Press the PROG button
(2) to enter and exit from the programming menu or wait
30 seconds to auto exit.
With the
(8) and
value:
IN = winter = heating mode
AUT = automatic = heating/cooling mode handling
SU = summer = cooling mode
Press the PROG button (2) to enter and return to the
programming menu, press the MODE button (9) to enter
and exit from the programming menu or wait 5 seconds
to auto exit.
Set the password (password for technical menu = 18)
using the
(8) and
PROG button (2) to enter.