PH10M-iQ PLUS installation and user's guide
www.renishaw.com
PH10M-iQ PLUS compatible probes
M8 touch-trigger probes
This range of probes utilises the M8 bush for mounting to the head. When used with the PH10M-iQ PLUS, one of the autojoint to M8 bush
extension bars or the PAA1 adaptor must be used.
Probe
TP2-5W
TP6*
TP20
TP200
* An autojoint version (TP6A) is also available
Multiwire (autojoint) probes
This range of probes is compatible with PH10M-iQ PLUS and utilise the Renishaw multiwired autojoint connection to the head. Inferred
qualification is not available when using a scanning probe with PH10M-iQ PLUS.
Probe
SP25M
TP7M
SP600M
Probes in this range require comprehensive integration with your CMM.
Issued 07 2021
Diameter
13 mm
25 mm
13.2 mm
13.5 mm
Diameter
Application
25 mm
High speed scanning
probe
25 mm
Universal probe with
strain gauge for DCC
CMMs
50 mm
Analogue contact
scanning probe
Application
Universal probe for DCC and
manual CMMs
Universal probe for DCC and
manual CMMs
Universal probe for DCC and
manual CMMs with module
changing
Universal probe with strain
gauge for DCC CMM - 100 mm
max stylus length
Weight
65 g (body)
35 g (SM25-1)
40 g (SM25-2)
49 g (SM25-3)
71 g (SM25-4)
45 g (SM25-5)
40 g (TM25-20)
85 g (without stylus)
216 g (without stylus)
User's guide
H-1000-5021
H-1000-5008
H-1000-5021
H-1000-5014
User's guide
H-1000-5104
H-1000-2010
H-1000-5175
20