Your Smart Energy
7.4.5 CT Connection
We provide a Grid-CT cable and a CT as accessory for DC-coupled systems.
Step 1: Insert the registered jack of the Grid-CT cable into the Grid-CT port on the
inverter
Step 2: Connect the other end of Grid-CT cable with the CT.
Step 3: Buckle the Grid-CT on the live wire of the house.
For AC-coupled systems and Hybrid-coupled systems, another PV-CT is needed to
buy. Buckle the PV-CT on the live wire of the PV inverter connecting point and insert
the registered jack of the PV-CT cable into the PV-CT port on the SMILE-S6-HV-INV.
NOTE:
The arrow of the CT should point to the grid port of the inverter from the grid or the PV
inverter.