Siemens CD634GA.0B User Manual And Installation Instructions page 22

Table of Contents

Advertisement

en Troubleshooting
Fault
Appliance prompting you to fill
water tank even though water
tank not yet empty/appliance not
prompting you to fill water tank
even though water tank empty.
A message that reads "Fill water
tank?" appears on the display
when the appliance is in opera-
tion.
"Appliance heating up" appears
on the display but the appliance
is not reaching the selected tem-
perature.
When cooking with steam, a lot
of steam is produced.
When cooking with steam, a lot
of steam is produced and this
happens repeatedly.
Steam escaping from ventilation
slots during cooking.
13.2 Replacing the cooking compartment
bulb
If the cooking compartment light has failed, replace the
cooking compartment bulb.
Note: Heat-resistant, 25-watt, 230 V halogen bulbs are
available from the after-sales service or specialist retail-
ers. Only use these bulbs. Hold the new halogen bulbs
only with a clean, dry towel. This increases the service
life of the bulb.
WARNING ‒ Risk of burns!
The appliance and its parts that can be touched be-
come hot during use.
Caution should be exercised here in order to avoid
touching heating elements.
Young children under 8 years of age must be kept
away from the appliance.
Never touch the ventilation openings.
WARNING ‒ Risk of electric shock!
When changing the bulb, the bulb socket contacts are
live.
Before replacing the bulb, ensure that the appliance
is switched off in order to prevent a potential electric
shock.
Also unplug the appliance from the mains or switch
off the circuit breaker in the fuse box.
Requirements
¡ The appliance must be disconnected from the power
supply.
¡ The cooking compartment must have cooled down.
¡ You must have a new halogen bulb to replace the
old one.
Turn the glass cover anti-clockwise to remove it  ⁠ .
1.
22
Cause and troubleshooting
Water tank dirty and moving water level indicators jammed.
Shake and clean the water tank.
1.
If the jammed parts cannot be freed, order a new water tank from our after-
2.
sales service.
Water tank half full.
No action required.
Automatic calibration values are not optimal.
Restore the appliance's factory settings and repeat the procedure for initial
configuration.
→ "Basic settings", Page 15
→ "Before using for the first time", Page 8
a The next time you use the Steam function at 100 °C, the calibration process
will run automatically and more steam will be produced.
The appliance is being automatically calibrated.
No action required.
Appliance unable to calibrate itself automatically if cooking times too short.
Restore the appliance's factory settings and repeat the calibration process.
This is standard procedure.
No action required.
Pull out the halogen bulb without turning it  ⁠ .
2.
Insert the new halogen bulb and press it firmly into
3.
the socket.
Make sure that the pins are positioned correctly.
Slide the new seals and the clamping ring onto the
4.
glass cover in the right order.
Screw the glass cover with the seals back on again.
5.
Never operate the appliance without the glass cover
and seals.
Connect the appliance to the power supply and fol-
6.
low the initial configuration procedure again.
13.3 Replacing the glass cover or seals
If the halogen bulb's glass cover or seals are dam-
aged, you must replace the damaged parts.
Replace the glass cover or seals.
You can obtain a new glass cover or new seals
from our after-sales service.
→ "Customer Service", Page 32

Advertisement