Quick Start - Bosch Solution 6+6 Wireless AE Quick Reference Manual

Table of Contents

Advertisement

Solution 6+6 Wireless - AE

Quick Start

The following steps will enable you to use the
values as set at the factory. The default settings allow the panel to communicate in Contact ID Format.
1.
Connect AC power to the unit.
The
indicator will remain on as will the
MAINS
2.
The battery should now be connected.
3.
Enter the default Master Code
The control panel is now in the disarmed state. Installer's Programming Mode can now be accessed.
4.
Enter the factory default Installer Code
indicator's will now flash simultaneously. Refer to "LOCATION 56 - 59" for the locations of the factory default
Installer's Code.
5.
Enter the primary, secondary telephone numbers and the Subscriber ID Number.
6.
Set the time for the test reports if this option is required. Any other programming changes required can also be
programmed, otherwise the programmed factory default settings will be used.
960
7.
Enter command
return to the disarmed state and is now ready for use. Refer to "Installer's Programming Commands" on page 6 for
further commands that can be performed during access of Installer's Programming Mode.
8.
If the
indicator on the remote codepad has illuminated or is flashing, a system fault has occurred. To clear
FAULT
any system fault that may have occurred, refer to "Fault Analysis Mode" on page 7 for more information.
9.
This step is optional however it use is recommended. Using a Master Code set the date and time.
Enter
Enter the day of the month, then the month, then the year, then the hour, then the minute using the format
(DD, MM, YY, HH, MM).
Press the
Zone Default Settings
The default zone settings are as listed in the table below.
Note:
The example given in this Quick Reference Guide is a simplified description of how to configure the
panel. The system offers many other programmable features which are described in greater detail in the
Solution 6+6 Wireless - AE Installation Manual (MA660I).
Quick Reference Guide
Solution 6+6 Wireless - AE
indicator. The unit is now in the armed state.
AWAY
2580
followed by the
1234
followed by the
6
+
+
.
button when the date and time has been entered.
Zone No.
1
Delay
2 & 3
Handover
4 & 5
Instant
24 Hour
6
Bosch Security Systems Pty Limited
button. The
followed by the
button to exit Installer's Programming Mode. The panel will
Zone Type
ISSUE 1.00
control panel with the default
AWAY
indicator will extinguish.
button. The
STAY
and
AWAY
Page 5