S+S Regeltechnik PREMASGARD 232 Series Operating Instructions, Mounting & Installation page 15

Pressure and differential pressure measuring transducers, incl. connection set, with modbus (tyr 3)
Hide thumbs Also See for PREMASGARD 232 Series:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 10
G
®
PREMASGARD
Function 06 Write Single Register & Function 16 Write Multiple Register
Register
Parameter (Display)
4x0002
7-Segment Value
4x0003
7-Segment Value
4x0004
4x0005
Segment Pattern
4x0006
Dot Matrix Character A
4x0007
Dot Matrix Character B
4x0008
Dot Matrix Character C
4x0009
Dot Matrix Character D
4x0010
Dot Matrix Character E
4x0011
Dot Matrix Character F
4x0012
Dot Matrix Character G
4x0013
Dot Matrix Character H
4x0014
Dot Matrix Character I
4x0015
Dot Matrix Character J
4x0016
Dot Matrix Character K
4x0017
Dot Matrix Character L
4x0018
Dot Matrix Character M
4x0019
Dot Matrix Character N
4x0020
Dot Matrix Character O
4x0021
Dot Matrix Character P
4x0022
Dot Matrix Character Q
Function 08 Diagnostics
The following sub function codes are supported
Sub Function
Parameter
Code
00
Echo of transmission data
(Loopback)
01
Restart Modbus
(Reset listen-only mode)
04
Activation listen-only mode
10
Delete counter
11
Counter bus telegrams
12
Counter communication errors
(Parity, CRC, frame errors, etc.)
13
Counter exception telegrams
14
Counter slave telegrams
15
Counter telegrams without answer
Function 17 Report Slave ID
Composition of answer telegram
Byte Nr.
Parameter
00
Number of bytes
01
Slave ID (device type)
02
Slave ID (device class)
03
Status
04
Version number (release)
05
Version number (version)
06
Version number (index)
232x - Modbus - T3 | Telegrams
Data Type
Value
Signed 16 Bit
–999...9999
Signed 8 Bit
–9...99
Unsigned 16 Bit
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Unsigned 8 Bit
0...255
Data Type
Answer
Echo data
Echo telegram
No answer
Echo telegram
Unsigned 16 Bit
All valid bus telegrams
Unsigned 16 Bit
Faulty bus telegrams
Unsigned 16 Bit
Error counter
Unsigned 16 Bit
Slave telegrams
Unsigned 16 Bit
Broadcast messages (address 0)
Data Type
Answer
Unsigned 8 Bit
6
Unsigned 8 Bit
13 = PREMASGARD
30 = PREMASGARD
Unsigned 8 Bit
Unsigned 8 Bit
255 = RUN, 0 = STOP
Unsigned 8 Bit
1...9
Unsigned 8 Bit
1...99
Unsigned 8 Bit
1
15
Range
–999...9999
–9...99
See Binary Pattern
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
ASCII character
®
232x
®
/ PREMASREG
®

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents