S+S Regeltechnik THERMASGARD ALTM1 Series Operating Instructions, Mounting & Installation

S+S Regeltechnik THERMASGARD ALTM1 Series Operating Instructions, Mounting & Installation

Surface contact/tube contact temperature measuring transducers, including strap, calibratable, with multi-range switching and active output
Hide thumbs Also See for THERMASGARD ALTM1 Series:
Table of Contents
  • Technische Daten
  • Wichtige Hinweise
  • Montage Et Mise en Service
  • Технические Данные
  • Монтаж И Подключение

Advertisement

Available languages

Available languages

  • ENGLISH, page 6
D G F r
6000-2720-0000-1XX 27200-2020 V104 05 ⁄ 2020
THERMASGARD
® 
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Anlegetemperaturmessumformer ⁄ Rohranlegefühler,
incl. Spannband, kalibrierfähig,
mit Mehrbereichsumschaltung und aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Surface contact ⁄ tube contact temperature measuring transducers,
including strap, calibratable,
with multi-range switching and active output
F
Notice d'instruction
Sonde de température d'applique pour conduites avec convertisseur,
y compris collier de serrage, étalonnable,
avec commutation multi-gamme et sortie active
r
Руководство по монтажу и обслуживанию
Датчик температуры накладной ⁄ накладной для труб,
вкл. хомут, калибруемый, с переключением между несколькими
диапазонами и активным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
ALTM 1
ALTM 2
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
ALTM 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the THERMASGARD ALTM1 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for S+S Regeltechnik THERMASGARD ALTM1 Series

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Page 2 D G F r ALTM 1 THERMASGARD ®  Maßzeichnung ALTM 1 Dimensional drawing Plan coté Габаритный чертеж M12-Steckverbinder (optional auf Anfrage) M12 connector (optional on request) connecteur M12 (en option et sur demande) разъем M12 (опционально по запросу) ohne Display M16x1.5 without display sans écran...
  • Page 3: Technische Daten

    ® THERMASGARD ALTM Rev. 2020 - V16 Kalibrierfähiger Anlegetemperaturmessumformer THERMASGARD ® ALTM 1 (Kompaktvariante) und ALTM 2 (abgesetzte Variante) mit acht umschaltbaren Messbereichen, stetigem Ausgang, im schlagfesten Kunststoffgehäuse mit Schnellverschlussschrauben, wahl weise mit ⁄ ohne Display, Kabelfühler mit Rohranleger (ALTM 2), incl. Spannband. Der Anlegefühler dient zur Erfassung der Temperatur an Leitungen, Rohren (z.B.
  • Page 4 Messumformer, kalibrierfähig, mit aktivem Ausgang Bürdendiagramm TEMPERATURBEREICHE: Bürdendiagramm Bei der Auswahl der Messumformerbereiche ist 4...20 mA darauf zu achten, dass die höchstzulässige Temperatur des Fühlers ⁄ Gehäuses nicht über schritten wird ! Umgebungstemperatur für den Messumformer: – 30 ...+ 70 °C zulässiger Bürdenwiderstand = siehe Bürdendiagramm Bereich...
  • Page 5: Wichtige Hinweise

    Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Der Einbau hat unter Beachtung der Übereinstimmung der vorliegenden Anschluss der Geräte darf nur an Sicherheitskleinspannung erfolgen. technischen Parameter der Thermometer mit den realen Einsatzbe- Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind von dingungen zu erfolgen, insbesondere: der Gewährleistung und Haftung ausgeschlossen.
  • Page 6: Technical Data

    ® THERMASGARD ALTM Rev. 2020 - V16 Calibratable surface-contact temperature measuring transducer THERMASGARD ® ALTM 1 (compact variant) and ALTM 2 (detached variant) with eight switchable measuring ranges, continuous output, in an impact-resistant plastic housing with quick-locking screws, optionally with ⁄ without display, cable sensor with a pipe feeder (ALTM 2), incl.
  • Page 7 Measuring transducers, calibrateable, with active output Load resistance diagram TEMPERATURE RANGES: Load resistance diagram When selecting measuring transducer ranges, 4...20 mA it is necessary to ensure that the maximum temperatures permissible for sensor ⁄ housing are not exceeded ! Ambient temperature for measuring transducers: –...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Before mounting, make sure that the existing thermometer‘s technical only be connected to safety extra-low voltage. Consequential damages parameters comply with the actual conditions at the place of utilization, caused by a fault in this device are excluded from warranty or liability.
  • Page 9 ® THERMASGARD ALTM Rev. 2020 - V16 Convertisseur de mesure de température d’applique étalonnable THERMASGARD ® ALTM 1 (version compacte) et ALTM 2 (version à épaulement), huit plages de mesure commutables, sortie analogique, boîtier en plastique résistant aux chocs avec vis de fermeture rapide, au choix avec / sans écran, sonde à...
  • Page 10 Convertisseur de mesure étalonnable avec sortie active Load resistance diagram PLAGES DE TEMPÉRATURE (TB): Sonde THERMASGARD ® ALTM 1 et ALTM 2, sonde de température d’applique pour conduites étalonnable avec convertisseur, huit plages de Diagramme de charge mesure commutables, sonde interne ou sonde de détection à distance, sortie analogique, collier de serrage et boîte à bornes en matière plastique Lors de la sélection des plages de convertisseur, 4...20 mA résiliente, couvercle de boîtier avec vis de fermeture rapide, en option avec ou sans écran.
  • Page 11: Montage Et Mise En Service

    Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Effectuer l’installation en respectant la conformité des paramètres Veillez à ne brancher l’appareil que sur un réseau de très basse tension techniques correspondants des thermomètres aux conditions d’utilisation de sécurité.
  • Page 12: Технические Данные

    ® THERMASGARD ALTM Rev. 2020 - V16 Калибруемый накладной измерительный преобразователь температуры THERMASGARD ® ALTM 1 (компактное исполнение) и ALTM 2 (выносное исполнение) с 8 переключаемыми диапазонами измерения, аналоговым выходом, в ударопрочном пластиковом корпусе с быстрозавора- чиваемыми винтами, на выбор с дисплеем или без дисплея, накладной кабельный датчик, вкл. стяжной хомут. Предназначен...
  • Page 13 Преобразователи измерительные, калибруемые, с активным выходом Load resistance diagram ТЕМПЕРАТУРНЫЕ ДИАПАЗОНЫ: Нагрузочная диаграмма При выборе диапазона для измерительного преобразователя 4...20 мA следует учитывать, что не разрешается превышение максимальной допустимой температуры датчика  ⁄ корпуса ! Температура окружающей среды для измерительного преобразователя: –...
  • Page 14: Монтаж И Подключение

    Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Монтаж следует осуществлять с учетом соответствия прилагаемых Подключение должно осуществляться исключительно к безопасно технических параметров термометра реальным условиям эксплуатации, малому напряжению. Повреждения приборов вследствие несоблюдения в особенности: упомянутых требований не подлежат устранению по гарантии; –...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r ALTM 1 THERMASGARD ®  ALTM 2 THERMASGARD ®  Anschlussbild ALTM - U Anschlussbild * ALTM - I DIP-Schalter DIP-Schalter Kontakt- Kontakt- Messbereichs- Messbereichs- seite seite umschaltung umschaltung 1 2 3 1 2 3 interner Sensor interner Sensor min.

Table of Contents