S+S Regeltechnik THERMASGARD ATM2-VA Operating Instructions, Mounting & Installation

S+S Regeltechnik THERMASGARD ATM2-VA Operating Instructions, Mounting & Installation

Outside temperature / wet room temperatre measuring transducers, calibratable, with multi-range switching and active output
Table of Contents
  • Technische Daten
  • Wichtige Hinweise
  • Montage Et Mise en Service
  • Технические Данные
  • Монтаж И Подключение

Advertisement

Available languages

Available languages

  • ENGLISH, page 6
D G F r
6000-5060-0000-1XX 50600-2020 V100 05 ⁄ 2020
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Außentemperatur ⁄ Feuchtraumtemperatur-
messumformer, kalibrierfähig,
mit Mehrbereichsumschaltung und aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Outside temperature ⁄ wet room temperature
measuring transducers, calibratable,
with multi-range switching and active output
F
Notice d'instruction
Sonde de température extérieure ⁄ de locaux humides
avec convertisseur, étalonnable,
avec commutation multi-gamme et sortie active
r
Руководство по монтажу и обслуживанию
Преобразователь температуры измерительный наружный ⁄
для помещений с повышенной влажностью, калибруемый,
с переключением между несколькими диапазонами
и активным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
ATM2 - VA
ID
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
ATM 2 - VAQ
ATM 2 - VA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the THERMASGARD ATM2-VA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for S+S Regeltechnik THERMASGARD ATM2-VA

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Page 2 D G F r ATM2 - VA THERMASGARD ®  Maßzeichnung ATM 2 - VA Dimensional drawing Plan coté Габаритный чертеж Gehäuse mit M12-Steckverbinder Gehäuse mit Kabelverschraubung Housing with M12 connector Housing with cable gland Boîtier avec connecteur M12 Boîtier avec presse-étoupe Корпус...
  • Page 3: Technische Daten

    ® THERMASGARD ATM 2 - VA ID Rev. ID20 - V12 (+U) Kalibrierfähiger Außentemperaturmessumformer THERMASGARD ® ATM 2 - VA mit acht umschaltbaren Messbereichen, externem Sensor, stetigem Ausgang, Gehäuse aus Edelstahl V4A, mit Kabelverschraubung oder M12-Steckverbinder nach DIN EN 61076-2-101. Er dient zur Erfassung der Außentemperatur, der Temperatur im Feuchtraumbereich, z.
  • Page 4 Messumformer, kalibrierfähig, mit aktivem Ausgang Bürdendiagramm TEMPERATURBEREICHE: Bürdendiagramm Bei der Auswahl der Messumformerbereiche ist 4...20 mA darauf zu achten, dass die höchstzulässige Temperatur des Fühlers ⁄ Gehäuses nicht über schritten wird ! Umgebungstemperatur für den Messumformer: – 30 ...+ 70 °C zulässiger Bürdenwiderstand = siehe Bürdendiagramm Bereich...
  • Page 5: Wichtige Hinweise

    Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Der Einbau hat unter Beachtung der Übereinstimmung der vorliegenden Anschluss der Geräte darf nur an Sicherheitskleinspannung erfolgen. technischen Parameter der Thermometer mit den realen Einsatzbe- Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind von dingungen zu erfolgen, insbesondere: der Gewährleistung und Haftung ausgeschlossen.
  • Page 6: Technical Data

    ® THERMASGARD ATM 2 - VA ID Rev. ID20 - V12 (+U) Calibratable outside temperature measuring transducer THERMASGARD ® ATM 2 - VA with eight switchable measuring ranges, external sensor, continuous output, housing made from stainless steel V4A, with cable gland or M12 connector according to DIN EN 61076-2-101. It is used to detect outside temperatures, temperatures in wet rooms, e.g.
  • Page 7 Measuring transducers, calibrateable, with active output Load resistance diagram TEMPERATURE RANGES: Load resistance diagram When selecting measuring transducer ranges, 4...20 mA it is necessary to ensure that the maximum temperatures permissible for sensor ⁄ enclosure are not exceeded ! Ambient temperature for measuring transducers: –...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Before mounting, make sure that the existing thermometer‘s technical only be connected to safety extra-low voltage. Consequential damages parameters comply with the actual conditions at the place of utilization, caused by a fault in this device are excluded from warranty or liability.
  • Page 9 ® THERMASGARD ATM 2 - VA ID Rev. ID20 - V12 (+U) Convertisseur de température extérieure étalonnable THERMASGARD ® ATM 2 - VA avec huit plages de mesure commutables, capteur externe, sortie continue, boîtier en acier inox V4A, avec presse-étoupe ou connecteur M12 selon DIN EN 61076-2-101. Il sert à mesurer la température extérieure, la température dans des zones humides, par ex.
  • Page 10 Convertisseur de mesure étalonnable avec sortie active Load resistance diagram PLAGES DE TEMPÉRATURE (TB): Diagramme de charge Lors de la sélection des plages de convertisseur, 4...20 mA il faut veiller à ce que la température maximale admissible de la sonde ⁄ du boîtier ne soit pas dépassée ! Température ambiante du convertisseur: –...
  • Page 11: Montage Et Mise En Service

    Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Effectuer l’installation en respectant la conformité des paramètres Veillez à ne brancher l’appareil que sur un réseau de très basse tension techniques correspondants des thermomètres aux conditions d’utilisation de sécurité.
  • Page 12: Технические Данные

    ® THERMASGARD ATM 2 - VA ID Rev. ID20 - V12 (+U) Калибруемый наружный измерительный преобразователь температуры THERMASGARD ® ATM 2 - VA с переключением между 8 диапазонами измерения, внешним датчиком, аналоговым выходом, корпус из высококачественной стали V4A, с резьбовым кабельным вводом или разъемом...
  • Page 13 Преобразователи измерительные, калибруемые, с активным выходом Load resistance diagram ТЕМПЕРАТУРНЫЕ ДИАПАЗОНЫ: Нагрузочная диаграмма При выборе диапазона для измерительного преобразователя 4...20 мA следует учитывать, что не разрешается превышение максимальной допустимой температуры датчика  ⁄ корпуса ! Температура окружающей среды для измерительного преобразователя: –...
  • Page 14: Монтаж И Подключение

    Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Монтаж следует осуществлять с учетом соответствия прилагаемых Подключение должно осуществляться исключительно к безопасно технических параметров термометра реальным условиям эксплуатации, малому напряжению. Повреждения приборов вследствие несоблюдения в особенности: упомянутых требований не подлежат устранению по гарантии; –...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r ATM2 - VA THERMASGARD ®  Anschlussbild ATM 2 - U VA Anschlussbild ATM 2 - I VA DIP-Schalter DIP-Schalter Messbereichs- Messbereichs- umschaltung umschaltung 1 2 3 1 2 3 interner Sensor interner Sensor min. max. min. max.