Genie GR-12 Operator's Manual page 42

Table of Contents

Advertisement

Operator's Manual
Operating Instructions
Emergency Stop
Push in the red Emergency Stop button to the off
position at the ground controls or the platform
controls to stop all functions.
Repair any function that operates when either red
Emergency Stop button is pushed in.
Auxiliary Lowering
Pull the auxiliary lowering knob to
lower the platform.
Operation from Ground
1
Be sure the battery pack is connected before
operating the machine.
2
Turn the key switch to ground control.
3
Pull out both ground and platform red
Emergency Stop buttons to the on position.
To Position Platform
1
At the control panel, press Enter button to
cycle between indoor and outdoor area of
operations.
Note: Area of operation can only be changed when
the machine is in the stowed position.
2
Press and hold the lift function enable.
3
Press the platform up or down button.
40
Operation from Platform
1
Be sure the battery pack is connected before
operating the machine.
2
Turn the key switch to platform control.
3
Pull out both ground and platform red
Emergency Stop buttons to the on position.
To Position Platform
1
Press the Indoor or
Outdoor use button.
Note: Area of operation can
only be changed when the
machine is in the stowed
position.
2
Press the lift function button. On the
LED screen, a circle below the lift
function symbol will turn on.
If the control handle is not moved within seven
seconds of pushing the lift function button, the
circle below the lift function symbol will turn off and
lift function will not operate. Press the lift function
button again.
3
Press and hold the function enable switch on
the control handle.
4
Move the control handle in the direction
indicated by the markings on the control panel.
-12 • GR
-15 • GR
GR
Sixth Edition • First Printing
-20
Part No. 1297723GT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr-15Gr-20

Table of Contents