ABB Relion 605 Series Applications Manual page 20

Feeder/motor protection and control
Hide thumbs Also See for Relion 605 Series:
Table of Contents

Advertisement

Section 2
REF601/REJ601/REM601 overview
14
Table 3:
List of event types and related description, continue
Sr.
Event type
No.
11
Blocking
12
Breaker
position
13
Memory read
fail
14
Hardware test
15
Binary output
test
16
Functional test
17
Power Off
18
Breaker Failure
Stage 1, 2
output
19
Breaker Failure
receive trip
output
20
Breaker Failure
receive trip
Acceptance
21
Setting group
change
22
Thermal reset
23
Thermal block
breaker close
24
O→I close
25
O→I FinalTr
26
O→I Blocked
27
O→I Stopped
28
O→I Started
29
Signal 1, 2, 3
Description
When blocking by binary input, And shall
have event for both rising & dropping
When breaker open, close or maintenance
position sensed by associated binary input
In case unable to read Event from EEPROM,
a message i.e. "Memory Read Fail" will be
displayed for that particular event
When in test menu, initiate hardware test
When in test menu , initiate binary output test
When in test menu, initiate protection
function test
When binary input is mapped to register
power off situation & power supply to IED
goes OFF.
On breaker failure receive stage 1 output
On breaker failure receive trip output
On Acceptance of BF RecTrip input
On change of setting group from one to
another
On reset of thermal function either from BI,
LHMI or communication.
On breaker close blocking output signal for
both rising & falling signal
On breaker close blocking output signal for
both rising & falling signal due to cumulative
startup protection
On O→I close output
On O→I final trip output
On O→I blocked output
On O→I stopped internal signal generated
On O→I started internal signal generated
On signal 1, 2, 3 output activation and
deactivation respectively
1MDU07212-YN Rev. D
Data considered
BI Blocking ↑
BI Blocking ↓
CB POS CLS ↑
CB POS CLS ↓
CB POS OPN ↑
CB POS OPN ↓
CB Maint ↑
CB Maint ↓
Memory Read Fail
Hardware Test
BO Test
Functional Test
Power Off
BF Stage1 ↑
BF Stage2 ↑
BF Stage1 ↓
BF Stage2 ↓
BF RecTrip BO↑
BF RecTrip BO↓
BF RecTrip Acp ↑
Setting SG Edt.
Setting SG No.
Setting SG Act.
3Ith> Reset
3Ith> Blk Cls ↑
3Ith> Blk Cls ↓
I2tn< BlkCl ↑
I2tn< BlkCl ↓
O→I close 1 ↑
O→I close 2 ↑
O→I close 3 ↑
O→I close 4 ↑
O→I FinalTr ↑
O→I Blocked ↑
O→I Blocked ↓
O→I Stopped ↑
O→I Started ↑
Signal 1 ↑
Signal 2 ↑
Signal 3 ↑
Signal 1 ↓
Signal 2 ↓
Signal 3 ↓
REF601 / REJ601 / REM601
Application Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion ref601Relion rej601Relion rem601