Set Up - Adjusting the VP321 Timing Controls
Vacuum Time: To increase or decrease the vacuum time, press the SET
button until VACUUM is illuminated and then use the UP/DOWN buttons to
adjust the vacuum time accordingly. The time setting will display on the
LED Screen on the control panel.
NOTE: Filler plates can be used to reduce the vacuum time required. Place the
filler plates inside the chamber as desired. Filler plates occupy space, leaving
less air to be removed from the chamber. If you require more space inside the
chamber, remove the filler plates to accommodate your product.
Sealing Time: To increase or decrease the sealing time, press the SET
button until SEALING is illuminated and then use the UP/DOWN buttons
to adjust the sealing time to accommodate your application. It is
recommended that you make adjustments in 0.1 second increments to
avoid melting the pouch.
NOTE: For thicker pouches, you should increase the seal time in 0.1 second
increments until the pouch seals completely. In addition, for thinner pouches,
you should decrease the seal time in 0.1 second increments to avoid over-sealing
the pouch.
Cooling Time: To increase or decrease the cooling time, press the SET
button until COOLING is illuminated and then use the UP/DOWN buttons to
adjust the cooling time accordingly.
NOTE: The VP321 settings will always default to the most recently used settings
on the machine.
TIP:
To prolong the life of your seal bar, set the cooling time to
twice the sealing time.