Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 V, 60 Hz, AC only 15 A or 20 A fused, grounded electrical
supply is required. It is recommended that a separate circuit
serving only your refrigerator be provided. Use an outlet that
cannot be turned off by a switch. Do not use an extension cord.
If the supply cord is damaged it must be replaced by the
manufacturer or its service agent or a similarly qualified person.
Do not use a cord that shows cracks or abrasion damage along its
length, or at either the plug or connector end.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, turn Cooling OFF, and then disconnect the
refrigerator from the electrical source. When you have finished,
reconnect the refrigerator to the electrical source and turn ON
Cooling. See "Using the Control(s)."

Water Supply Requirements

A cold water supply with water pressure between
30 psi and 120 psi (207 kPa and 827 kPa) is required to operate
the water dispenser and ice maker. If you have questions about
your water pressure, call a licensed, qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out
of a reverse osmosis system going to the water inlet valve
of the refrigerator needs to be between 30 psi and 120 psi
(207 kPa and 827 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis system
needs to be a minimum of 40 psi to 60 psi (276 kPa to 414 kPa).
If the water pressure to the reverse osmosis system is less than
40 psi to 60 psi (276 kPa to 414 kPa):
Check to see whether the sediment filter in the reverse osmosis
system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage. The tank capacity could be too low to keep
up with the requirements of the refrigerator.
If your refrigerator has a water filter, it may further reduce the
water pressure when used in conjunction with a reverse osmosis
system. Remove the water filter. See "Water Filtration System."

Connect the Water Supply

Read all directions before you begin.
IMPORTANT:
Connect to potable water supply only.
Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction
may be used on disinfected waters that may contain
filterable cysts.
If you turn the refrigerator on before the water line is
connected, turn the ice maker OFF.
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Flat-blade screwdriver
7/16" and 1/2" Open-end or
two adjustable wrenches
NOTE: Your refrigerator dealer has a kit available with a
1/4" (6.35 mm) saddle-type shutoff valve, a union, and copper
tubing. Before purchasing, make sure a saddle-type valve complies
with your local plumbing codes. Do not use a piercing-type or
3/16" (4.76 mm) saddle valve which reduces water flow and clogs
more easily.
Connect to Water Line
Style 1
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long
enough to clear line of water.
3. Locate a 1/2" to 11 /
" (1.25 cm to 3.18 cm) vertical cold water
4
pipe near the refrigerator.
IMPORTANT:
■ Make sure it is a cold water pipe.
■ Horizontal pipe will work, but drill on the top side of the
pipe, not the bottom. This will help keep water away from
the drill and normal sediment from collecting in the valve.
4. Determine the length of copper tubing you need. Measure
from the connection on the lower left rear of refrigerator to the
water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use 1/4"
(6.35 mm) O.D. (outside diameter) copper tubing. Be sure both
ends of copper tubing are cut square.
5. Using a cordless drill, drill a 1/4" hole in the cold water pipe
you have selected.
G
F
E
A. Cold water pipe
B. Pipe clamp
C. Copper tubing
D. Compression nut
1/4" Nut driver
1/4" Drill bit
Cordless drill
A
B
C
D
E. Compression sleeve
F. Shutoff valve
G. Packing nut
9