Power Supply
STEEL PRO POWER
Installation, technical assistance service and system management manual
Riello STEEL PRO POWER Installation, Technical Assistance Service And System Management Manual page 57
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
page
of
59
Go
/
59
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
SYSTEM MANAGER
MODBUS CONNECTION
Status parameters
Access
Register
Automatic
Description
number
conversion
L
S
100
X
State
101
X
Status
102
X
Error code
103
X
Alarm code
Heating
110
X
Yes
pump
111
X
DHW pump Yes
Module
112
X
Yes
pump
Temperatures/Information
Access
Register
Automatic
Description
number
conversion
L
S
Delivery
120
X
Yes
temperature
Return tem-
121
X
Yes
perature
DHW tem-
122
X
Yes
perature
Flue gas
123
X
Yes
temperature
System
tempera-
124
X
Yes
tures (where
available)
Outdoor
tempera-
125
X
Yes
ture (where
available)
140
X
Power
Yes
Minimum
141
X
Yes
output
Ionisation
142
X
Yes
current
Dependent information
Access
Value
Register
Automatic
Description
range
number
conversion
L
S
See "State"
Dependent 01
table
300
X
State
See "Sta-
tus" table
302
X
Error code
See "Error"
303
X
Power
Yes
tables
Dependent 02
See "Warn-
ing" table
306
X
State
0/100 or
308
X
Error code
0..100%
309
X
Power
Yes
0/100 or
Dependent 03
0..100%
0/100 or
312
X
State
0..100%
314
X
Error code
315
X
Power
Yes
Value
Dependent 04
range
318
X
State
Depends
on °C/°F
units
320
X
Error code
Depends
on °C/°F
321
X
Power
Yes
units
Dependent 05
Depends
on °C/°F
324
X
State
units
Depends
326
X
Error code
on °C/°F
units
327
X
Power
Yes
Dependent 06
Depends
on °C/°F
330
X
State
units
332
X
Error code
Depends
333
X
Power
Yes
on °C/°F
units
Dependent 07
0..100%
336
X
State
0..100%
338
X
Error code
339
X
Power
Yes
0..x μA
Dependent 08
342
X
State
344
X
Error code
345
X
Power
Yes
112
SYSTEM MANAGER
Access
Register
Description
number
L
S
Value range
Dependent 09
348
X
State
See "State"
table
350
X
Error code
See "Error"
tables
351
X
Power
0..100%
Dependent 10
354
X
State
See "State"
table
356
X
Error code
See "Error"
tables
357
X
Power
0..100%
Dependent 11
360
X
State
See "State"
table
362
X
Error code
See "Error"
tables
363
X
Power
0..100%
Dependent 12
366
X
State
See "State"
table
368
X
Error code
See "Error"
tables
369
X
Power
0..100%
Dependent 13
372
X
State
See "State"
table
374
X
Error code
See "Error"
tables
375
X
Power
0..100%
Dependent 14
378
X
State
See "State"
table
380
X
Error code
See "Error"
tables
381
X
Power
0..100%
Dependent 15
384
X
State
See "State"
table
386
X
Error code
See "Error"
tables
387
X
Power
0..100%
See "State"
table
See "Error"
tables
0..100%
Parameters registers
Automatic
Value range
Access
conversion
Register
Description Note
number
L
S
See "State"
Heating
table
500
X
X
mode
See "Error"
(Par. 1)
tables
DHW
Yes
0..100%
501
X
X
mode
(Par. 35)
See "State"
Heating
table
502
X
X
set-point
See "Error"
(Par. 3)
tables
Yes
0..100%
DHW
503
X
X
set-point
(Par. 48)
See "State"
table
Set-point
See "Error"
at min.
504
X
X
tables
climatic T
(Par. 19)
Yes
0..100%
Set-point
See "State"
at max.
table
505
X
X
climatic T
See "Error"
(Par. 21)
tables
Yes
0..100%
Out. tem-
perature
506
X
X
for climatic
See "State"
minimum
table
(Par. 22)
See "Error"
tables
Yes
0..100%
Out. tem-
perature
507
X
X
for climatic
See "State"
maximum
table
(Par. 20)
See "Error"
tables
Climatic
Yes
0..100%
508
X
X
shut-off
(Par. 25)
See "State"
table
Maximum
value that
See "Error"
can be
tables
assigned
509
X
X
Yes
0..100%
to the
heating
set-point
(Par. 24)
113
MODBUS CONNECTION
Automatic
Value
conversion
range
NV
0..x
NV
0..x
Depends
V
Yes
on °C/°F
units
Depends
V
Yes
on °C/°F
units
Depends
NV
Yes
on °C/°F
units
Depends
NV
Yes
on °C/°F
units
Depends
NV
Yes
on °C/°F
units
Depends
NV
Yes
on °C/°F
units
Depends
NV
Yes
on °C/°F
units
Depends
NV
Yes
on °C/°F
units
Table of
Contents
Previous
Page
Next
Page
1
...
54
55
56
57
58
59
Advertisement
Table of Contents
Related Manuals for Riello STEEL PRO POWER
Power Supply Riello DVT 50 User Manual
Dialog vision 500 - 3000 va (34 pages)
Related Products for Riello STEEL PRO POWER
Riello Start 24 KI
Riello START 28 KI
Riello START 24 KIS
Riello START 28 KIS
Riello START 35 KIS
Riello START KIS Series
Riello Sentinel Dual SDH 1500
Riello SDH 3000
Riello AARIA MONO S3 35
Riello Design Inverter S 11B
Riello DB 6 SM CO1 A0
Riello S008T2
Riello S009T1
Riello SEP 1000 ER NP
Riello SDH 1000
Riello SDH 1500
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL