Summary of Contents for Riello DVT 50

  • Page 2 USER MANUAL...
  • Page 3: Table Of Contents

    ONTENTS INTRODUCTION PRESENTATION HARACTERISTICS RONT VIEW EAR VIEW INSTALLATION PENING THE UPS PACKAGING AND CHECKING THE CONTENTS PENING THE ATTERY OX PACKAGING AND CHECKING THE CONTENTS HECKING THE EQUIPMENT LACING THE UPS NSTALLING THE ERTICAL INSTALLATION OF THE MODELS ERTICAL INSTALLATION OF THE MODELS WITH BATTERY BOX OSITIONING THE RONT...
  • Page 4 ONTENTS RS232 INTERFACE PORT OMMUNICATION SOCKET SOFTWARE ONITORING AND CONTROL SOFTWARE ONFIGURATION SOFTWARE ALARMS AND INDICATORS REPLACING THE BATTERY IALOG ISION OWER IALOG ISION IALOG ISION SPECIFICATIONS...
  • Page 5: Introduction

    NTRODUCTION Thank you for choosing our Uninterruptible Power Supply (UPS). Our company is highly specialised in the development and production of uninterruptible power supplies (UPS). The UPS in this range are high quality products, designed and built with care to ensure optimum performance. This equipment can be installed by anyone, subject to a CAREFUL AND THOROUGH READING OF THIS MANUAL.
  • Page 6 RESENTATION This manual describes the Dialog Vision UPS family (DVT, DVR, DVD) and their related battery box. The Dialog Vision is a line-interactive UPS. The UPS protects equipment connected to it from: a) mains power supply failures b) surges c) sags and brownouts The UPS automatically corrects its output for small fluctuations in the mains power supply.
  • Page 7: Presentation

    2000 1100 1500 2200 3000 Nominal power 1050 1350 1050 1540 2100 Nominal output [Vac] 200/208/220/230/240 voltage Dimensions 438X44X460 438X88X582 [mm] 110X240X395 160X240X435 LxHxD (19”x1Ux460) (19”x2Ux582) RONT VIEW DVT 50/80/110 DVT 150/200 DVR 50/80/110 DVD 150/220/300 Dialog Vision Battery Box...
  • Page 8: Rear View

    RESENTATION EAR VIEW DVT 50/80/110 DVT 150/200 DVR 50/80/110 DVD 150...
  • Page 9 RESENTATION DVD 220/300 Dialog Vision Battery Box 1. RS232 serial interface 2. Cooling fan 3. Net/Tel protection 4. Input thermal protection 5. IEC network input plug 6. IEC output plug (max 10A) 7. Expansion slots for interface cards 8. Battery expansion connector 9.
  • Page 10: Installation

    NSTALLATION PENING THE UPS PACKAGING AND CHECKING THE CONTENTS After opening the packaging, check the contents. The packaging should contain the following: Plastic supports (DVD model only) Guides for rack installation + handles kit IEC 10A power cable (IEC 16A for DVD models (models DVR and DVD only) 220/300 only) IEC 16A loose plug (DVD 2200/3000 VA...
  • Page 11: Opening The Batteryb

    NSTALLATION PENING THE ATTERY OX PACKAGING AND CHECKING THE CONTENTS After opening the packaging, check the contents. The packaging should contain the following: Battery Box Guides for rack installation + handles kit UPS – Battery Box connection cable User manual + Warranty card Plastic supports + extensions...
  • Page 12: Checking The Equipment

    NSTALLATION HECKING THE EQUIPMENT Check the UPS carefully. If the UPS has been damaged during transit, keep the box and the packaging. Let the carrier and the supplier know immediately. LACING THE UPS This UPS must have an adequate airflow. It must be placed in a clean indoor environment with no humidity, away from flammable liquids and direct sunlight.
  • Page 13 NSTALLATION ERTICAL INSTALLATION OF THE MODELS WITH BATTERY BOX 1. Assemble the supports and the extension as shown in the figure. 2. Put the UPS and the battery box in a vertical position and place the two supports close to them. 3.
  • Page 14 NSTALLATION OSITIONING THE RONT ANEL MODELS The DVD LCD can be rotated to suit the kind of installation (rack or tower). The information below explains how to rotate the display: B. From Tower to Rack A. From Rack to Tower 1.
  • Page 15: Installing Dvr And Dvd

    NSTALLATION NSTALLING MODELS IN A RACK CABINET The DVR and DVD models can be installed in a 19” rack cabinet. The installation procedure is described below 1. Align and screw the handles onto the sides of the UPS. 2. Secure the guides onto the rack cabinet supports with the screws. 3.
  • Page 16: Connection

    NSTALLATION ONNECTION Connect the UPS to the mains power supply using the input supply cable. Connect the loads to the UPS sockets with the IEC-IEC cables or with a similar cable with a maximum length of 10 metres. Note: do not connect loads that draw more than 10A, to the 10A IEC sockets. These loads can only be connected to the 16A IEC socket (where fitted).
  • Page 17: Nstalling The Mergency

    NSTALLATION (EPO) NSTALLING THE MERGENCY OWER The DVR and DVD range are provided with an EPO contact. This allows the UPS to be shut down immediately without having to wait for the shutdown procedure to be completed. Note: When the UPS has been switched off using this input, it is not be possible to switch the device back on again (even if the EPO contact is closed) until the UPS has been restarted manually.
  • Page 18: Start - Up /Shutdown

    NSTALLATION 2. Then connect the other end of the cable to the battery connector at the back of the UPS. 3. To add further battery boxes (up to a total maximum capacity of 120Ah), repeat the previous steps. Note: When a battery box is installed, the UPS must be configured for the correct total capacity of the batteries (using UPSTools software) in order to calculate correctly the remaining back-up time and the battery charge.
  • Page 19: System Description

    YSTEM DESCRIPTION RONT PANEL The front panel consists of a display and “ON”, “OFF” and “SELECT” keys. Front panel ON button OFF button SELECT button Part A Part B Part D Part C...
  • Page 20 YSTEM DESCRIPTION The display can show two values at the same time, which can be selected from those available in part A and part B of the display. Detailed description for Part A (on the left): Part A ① INPUT-VAC : input voltage (unit: Volt) ②...
  • Page 21: Lcd Indicators

    YSTEM DESCRIPTION INDICATORS This chapter provides a detailed description of all the display indicators. ICON STATE DESCRIPTION Steady on Indicates a fault (see table 3) Flashing The UPS is in stand-by mode Steady on The UPS is operating in mains mode The UPS is operating in battery mode.
  • Page 22 YSTEM DESCRIPTION Table 1 Battery level 0%~20% 20%~40% 40%~60% 60%~80% 80%~100% Table 2 Applied load level 0~5% 5~25% 25%~50% 50%~75% 75%~102% >102% flashing In the event of an overload, the UPS will continue to power the load for a set period of time. The UPS will emit an alarm to signal that it can no longer support the overload (a beep at regular one-second intervals).
  • Page 23: Fault Signalling

    YSTEM DESCRIPTION AULT SIGNALLING All Dialog Vision models are provided with a self-check system that can indicate any faults or failures on the display. The symbols are shown below, together with a description and the possible solutions to rectify the problem.
  • Page 24 YSTEM DESCRIPTION Shown below is an example of the procedure to set the display to show the “Input voltage” on the left side of the display (Part A) and “Capacity as a percentage of the battery” on the right side (Part B). Configuration example: Press SELECT to change the field...
  • Page 25 YSTEM DESCRIPTION COUSTIC SIGNALS DESCRIPTION BEEP BUZZER STATUS a) Fault (e.g. due to overheating or fan failure) Continuous 1 2 3 4 5 6 7 8 9 10 b) Battery overcharged Continuous 1 2 3 4 5 6 7 8 9 10 Intermittent c) Overload (1s on/1s off)
  • Page 26: Rs232 Interface

    OMMUNICATION PORT RS232 INTERFACE With the RS232 serial interface the UPS can be connected to a PC (COM interface) by means of a pin-to-pin serial cable (if a different cable is used, this must be of the pin-to-pin type with a maximum length of 3 metres). The interface (with factory settings) has the following characteristics: RS232 CONNECTOR 3 4 5...
  • Page 27: Software

    OFTWARE The CD-Rom provided includes two programs that enable the user to carry out monitoring, control and configuration operations on the UPS. ONITORING AND CONTROL SOFTWARE The Powershield software provides UPS management, control and application shutdown, it ensures effective and intuitive UPS management by displaying all the necessary data values, such as input voltage, applied load, battery capacity.
  • Page 28: Alarms And Indicators

    LARMS AND INDICATORS UPS ACOUSTIC SIGNAL TABLES Signal Cause Solution 1 beep every 4 The UPS is operating in Check the input voltage seconds battery mode 1 beep per The battery is discharging Save your work and switch off the equipment second Overload in output Check the charge level indicator and remove some loads...
  • Page 29: Replacing The Battery

    EPLACING THE ATTERY When the battery fault indicator illuminates and the UPS emits an intermittent beep (one second on/ one second off), the battery may need to be replaced. Check the battery connection or contact the reseller to order a new battery.
  • Page 30: Dialog Vision Rack

    EPLACING THE ATTERY IALOG ISION 1. Remove the front panel of the UPS by pulling with both hands. 2. Disconnect the UPS battery cable. 3. Undo the screws securing the support to the UPS and remove the plate securing the batteries. 4.
  • Page 31: Dialog Vision Dual

    EPLACING THE BATTERY IALOG ISION 1. Remove the front panel of the UPS by pulling with both hands. 2. Undo the screws securing the support to the UPS and remove the plate securing the batteries. 3. Disconnect the cable. 4. Remove the batteries on a flat surface. 5.
  • Page 32 PECIFICATIONS Dialog Vision Tower MODEL DVT 50 DVT 80 DVT 110 DVT 150 DVT 200 1100 1500 2000 NOMINAL POWER Watt 1050 1350 Nominal voltage 230 VAC 160VAC ± 3% Voltage range INPUT 294VAC ± 3% Frequency 50/60Hz Automatic selection...
  • Page 33: Specifications

    PECIFICATIONS Dialog Vision Rack Dialog Vision Dual MODEL DVR 50 DVR 80 DVR 110 DVD 150 DVD 220 DVD 300 1100 1500 2200 3000 NOMINAL POWER Watt 1050 1540 2100 Nominal voltage 230 VAC 160VAC ± 3% INPUT Voltage range 294VAC ±...