YASKAWA VS mini J7 Replacement Instructions Manual page 13

Hide thumbs Also See for VS mini J7:
Table of Contents

Advertisement

Drive
Function/
Parameter
Parameter
No.
DC injection braking
n52
current
DC injection time at
n53
stop
DC injection time at
n54
start
Stall prevention during
n55
deceleration
Stall prevention level
n56
during acceleration
Stall prevention level
n57
during run
Output frequency
n58
detection level (DO)
Over torque detection
n59
Over torque detection
n60
level
Over torque detection
n61
time
Frequency reference
hold selection
n62
(up/down function)
Torque compensation
n63
gain
Motor rated slip
n64
Motor no-load current
n65
Slip compensation
n66
gain
Slip compensation
n67
time constant
Memobus
communication error
n68
behavior selection
Memobus
communication error
detection
n69
Memobus frequency
reference and monitor
units
J7
J1000
Parameter
Initial Value
No.
50%
b2-02
0.5 s
b2-04
0.0 s
b2-03
0
L3-04
170%
L3-02
160%
L3-06
0.0 Hz
L4-01
0
L6-01
160%
L6-02
0.1 s
L6-03
0
d4-01
1.0
C4-01
E2-02
E2-03
0.0
C3-01
2.0 s
C3-02
H5-04
H5-05
0
C1-02
C1-09
H5-05
0
H5-13
VAN-V07007E  [J7→J1000] Replacement Instructions
Comments
Initial Value
50%
0.50 s
0.00 s
J7
n55→0
1
n55→1
Initial value of J1000 depends on Duty
-
mode selection (C6-01).
Initial value of J1000 depends on Duty
-
mode selection (C6-01)
0.0 Hz
J7
n59→0
n59→1
0
n59→2
n59→3
n59→4
150%
0.1 s
J7
n62→0
0
n62→1
1.00
Default value depends on the drive rating.
-
Default value depends on the drive
capacity.
-
Set E2-03 = n32 * n65 / 100%
0.0
J7: Setting unit is 1.0 s
2000 ms
J1000: Setting unit is 1 ms
J7
3
n68→0
0
n68→1
n68→2
10.0
n68→3
100
n68→4
J7
n69→0
1
n69→1
n69→2
0
n69→3
J1000
L3-04→1
L3-04→0
J1000
L6-01→0
L6-01→1
L6-01→3
L6-01→2
L6-01→4
J1000
d4-01→0
d4-01→1
J1000
H5-04
H5-05
1
0 (C1-02)
1
2 (C1-09)
3
0
No effect
J1000
H5-13→0
H5-13→1 and
o1-03→0
H5-13→2
H5-13→3
13/16

Advertisement

Table of Contents
loading

This manual is also suitable for:

J1000