5831 Series Low Energy Operator
Wireless Interface Module (ADA1028W)
System Description:
The Wireless Interface Module allows the 5831 Series
door operator to interface to 5800 wired or wireless
push buttons, wireless remote, an electric lock, fire panel,
access control, and an outside push button disable
contact .
Mounting:
The WIM (108mm x 146mm) is designed to fit inside a
power supply cabinet .
Inputs:
•
Power input: 24VDC
•
Hardwire push buttons input: separate INSIDE and an
OUTSIDE activation input
•
Wireless push button input: separate INSIDE and an
OUTSIDE RF activation input
•
Operator connection cable: Plug in 5831 Series swing door
cable connector interface
•
Lock power: Dry contact SPDT to power an electric lock
•
Outside push button disable: privacy feature
Outputs:
•
Wireless Output: RF signal to activate door opener
•
Output Contacts: SPDT dry contact output for AUX signal
•
Lock Contacts: SPDT dry contact output for LOCK
•
Access Control Contacts: indicates valid Unlock signal
•
Signal Delay Timer: 1 .5 second lock release delay
•
Emergency Interface Relay (EIR): disables signal inputs
10
Lockwood Product Catalogue | 5831 Series Low Energy Operator
1300 LOCK UP (1300 562 587) lockweb.com.au
Technical Information: wiring diagrams
Electric Strike with RF or Wired Push Buttons
and Card Reader (or other Access Control)
INSIDE
OUTSIDE
BUTTON
BUTTON
WIRELESS RF
CONNECTION
OPTIONAL
HARDWIRED
CONNECTION
INSIDE
OUTSIDE
DOOR
BUTTON
BUTTON
OPERATOR
INSIDE BUTTON
O UTSIDE BUTTO N
PRESS & RELEASE
PRESS & RELEASE
T O LEARN
T OL EARN
HOLD T O ERASE
HO L D T O ERASE
OPERATOR
SIGNAL
SIGNAL
DELAY
POWER IN
12 OR 24V
Wiring the WIM and Operator
OPTIONAL
HARDWIRED
CONNECTION
CARD
READER
(ACCESS CONTROL)
ALARM
PANEL
FAIL SECURE
FAIL SAFE
LOCK
POWER
SUPPLY