3. Ceiling Fan Assembly
3.4
Remove the Hanger Ball by loosening the Phillips Head
Set Screw in the Hanger Ball until the Ball falls freely
down the Downrod (Figure 4).
Remove the Pin from the Downrod, then remove the
Hanger Ball (Figure 4).
Retain the Pin and Hanger Ball for reinstallation in
Step 3.13.
NOTE: If you have an eight-foot ceiling, you will
have to use the 6" Downrod (supplied) in order to
maintain the necessary blade-to-floor clearance of
seven feet.
The Three Decorative Rod Assemblies and the
Rod Support Assembly will not be installed on a
6" Downrod.
3.5
Turn the partially assembled Ceiling Fan over and position
it on the lower foam pad. The Lower Housing should be
resting on the pad so that the top of the motor faces up.
3.6
Separate, untwist and unkink the Three 80" Motor
Wires.
Route the Three 80" Black, Blue, and White Motor
Wires through the Downrod (Figure 5).
3.7
Loosen the Two Phillips Head Set Screws in the Motor
Coupler for installation of the Downrod (Figure 6).
Seat the Downrod in the Motor Coupler (Figure 6).
Rotate and align the Downrod holes with all the holes in
the Motor Coupler (Figure 6).
(Continued)
PIN
PHILLIPS HEAD SET SCREW (LOOSENED)
Figure 4
THREE 80" MOTOR
WIRES (UNTWISTED)
Figure 5
LOOSEN PHILLIPS
HEAD SET
SCREWS (2)
Figure 6
6
GREEN GROUND WIRE
DOWNROD
HANGER BALL
DOWNROD
DOWNROD
MOTOR
MOTOR
COUPLING
COUPLER
U.L. Model No.: CF205L-1