Carlisle Ransburg 9060 Service Manual page 21

Classic high voltage controller
Hide thumbs Also See for Ransburg 9060:
Table of Contents

Advertisement

EN
2. Open the Controller cabinet door.
3. The flow switch should have the ground (green) lead
connected to the ground screw on the base plate shown
in Figure 13. The trigger signal (blue) lead should be
connected to the trigger signal input on the J3-5 plug
header that is connected to the PC board. The trigger
signal lead should have a white ferrite attached to the
lead close to the J3-5 plug.
4. Verify that J5, shown on Figure 14, has the shunt
covering pins 1 and 2.
5. Secure the cabinet door, replace the fuses, and
reconnect the AC source.
Ground Screw
Figure 13: Ground Screw on Base Plate
Figure 14: PC Mainboard Jumper J5 Location
CP-13-06-R5 (09/2018)
Pin 1
21 / 34
INSTALLATION
www.carlisleft.com