examples.
-
The Modbus TCP device of address 0x01 is only able to be connected with the
ZT-2571 of Node ID 0x0001.
-
The Modbus TCP device of address 0x02 is only able to be connected with the
ZT-2571 of Node ID 0x0002. ... and so on
Ethernet Connection
O
ZT-2570
Controller
(10.1.0.2)
(10.1.0.1)
1. When the ZT-2571 acts the TCP client, there is only one Modbus TCP device
can be connected to the ZT-2571.
-
Such as the ZT-2571 acts TCP client to connect with the ET-7000.
2. The standard of ZigBee does not include the TCP/IP protocol, so the whole
Ethernet packets cannot be sent over the ZigBee wireless communication. In
the other words, the two separate local area network will not be linked
together into one LAN via the ZigBee wireless communication.
-
As the described above, the LANs of ZT-2570 and ZT-2571 are independent. So,
no matter which Modbus TCP devices you want to connect, all the connection
target should be changed to the IP address of ZT-2570.
-
In the origin architecture, the Modbus TCP devices are distinguished via
ICP DAS, ZT-2570/ZT-2571 User Manual, Version 1.3
Copyright @ 2013 by ICP DAS Co., Ltd. All Rights Reserved.
X
ET-7000
ZT-2571
(192.168.0.2)
(192.168.0.1)
ZT-2571
ET-7000
(192.168.0.2)
(192.168.0.1)