IMPORTANT:
BEFORE
INSTALLING:
Size of Door & Door Closer
Type
of
Interior
In-swinging
Installation
' "
2 4
' "
2 6
Parallel
' "
3 0
Arm
' "
3 6
' "
4 0
' "
4 6
**NOTE: These forces are for standard templating with bearing type hinges and do not account for pressure differentials and draft.
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2013, 2018 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Approved 2018-01-19
An improperly installed or incorrectly adjusted door closer may cause property
damage or personal injury; and will void product warranty.
To avoid personal injury, DO NOT DISASSEMBLE THIS DOOR CLOSER BODY.
Door closers must be securely fastened to a properly reinforced door and frame
with fasteners provided.
An auxiliary door stop, BY OTHERS, is required for this Installation.
The Americans with Disabilities Act (ADA) requires that doors having door closers
have an opening force not to exceed 5 lbf.
The door closer's power size adjustment feature may require adjustment to its
lowest setting to comply with ADA opening force guidelines.
ADA compliant closer: 9510.
Exterior
Exterior
Out -swinging
' "
2 6
' "
3 0
' "
*3 6
' "
*4 0
**Max.
Opening
Recommended
Force
Closer Size
lbs/f
1
8
2
14
3
16
4
22
5
24
6
26
Page 2
ASSA ABLOY
TO DETERMINE
HAND OF
YOUR DOOR:
RHR
RIGHT
LEFT
HAND
HAND
DOOR
DOOR
80-9395-9513-020 REV. 2 (01-18)