Download Print this page

Installation - Oriental motor CVD Series Operating Manual

Drivers for 2-phase, 5-phase stepping motors
Hide thumbs Also See for CVD Series:

Advertisement

z Driver with mounting plate
No.1: 1P/2P switch (pulse input mode)
No.2: OFF/SD switch (smooth drive function)
No.3: R2/R1 switch (resolution)
No.4: STOP switch (standstill current rate)
No.5: OFF/FIL switch (command lter)
No.6: Not used.
Cutouts for mounting B
(2 places)
STEP switch
(step angle)
RUN switch
(operating current rate)
PWR/ALM LED
z Driver with mounting plate Right angle type
No.1: 1P/2P switch (pulse input mode)
No.2: OFF/SD switch (smooth drive function)
No.3: R2/R1 switch (resolution)
No.4: STOP switch (standstill current rate)
No.5: OFF/FIL switch (command lter)
No.6: Not used.
Cutouts for mounting B
(2 places)
STEP switch
(step angle)
RUN switch
(operating current rate)
PWR/ALM LED

Installation

„ Installation location
The driver is designed and manufactured to be incorporated in equipment.
Install it in a well-ventilated location that provides easy access for inspection.
The location must also satisfy the following conditions:
y Inside an enclosure that is installed indoors (provide vent holes)
y Operating ambient temperature 0 to +50 °C (+32 to +122 °F) (non-freezing)
y Operating ambient humidity 85 % or less (non-condensing)
y Area free of explosive atmosphere, toxic gas (such as sulfuric gas), or liquid
y Area not exposed to direct sun
y Area free of excessive amount of dust, iron particles or the like
y Area not subject to splashing water (rain, water droplets), oil (oil droplets)
or other liquids
y Area free of excessive salt
y Area not subject to continuous vibrations or excessive shocks
y Area free of excessive electromagnetic noise (from welders, power
machinery, etc.)
y Area free of radioactive materials, magnetic fields or vacuum
y 1,000 m (3,300 ft.) or lower above sea level
4
CN1 connector
(power supply)
CN2 connector
(motor)
CN3 connector
(I/O signal)
Cutouts for mounting A
(4
places)
CN1 connector
(power supply)
CN2 connector
(motor)
CN3 connector
(I/O signal)
Cutouts for mounting A
(4 places)
„ Installation direction
Install the driver on a metal plate having excellent vibration resistance in
vertically or horizontally. If the driver is installed under conditions other than
vertical or horizontal position, its heat radiation effect will deteriorate.
The items shown below are necessary in order to install the driver. The items
are not included and must be provided by the customer.
Torque the mounting screw to 0.5 N·m (71 oz-in).
Driver type
M3 screw
M3 spring washer
M3 nut (Not necessary if screw
holes are provided in the
enclosure.)
Spacer [5 mm (0.2 in.) or larger]
There must be clearances of at least 25 mm (0.98 in.) and 50 mm (1.97 in.)
in the horizontal and vertical directions respectively, between the driver
and enclosure or other equipment within the enclosure. When two or more
drivers are to be installed side by side, provide clearances in the horizontal
and vertical directions as shown in the figure.
y Install the driver inside an enclosure.
y Do not install any equipment that generates a large amount of heat
or noise near the driver.
y If the ambient temperature of the driver exceeds 50 °C (122 °F),
reconsider the ventilation condition.
• Horizontal installation
The figure shows the driver with mounting plate.
* Provide 40 mm (1.57 in.) clearances for the "driver with mounting plate" of
Type A.
• Vertical installation
The figure shows the driver with
mounting plate right angle type.
Driver without
Driver with
mounting plate
mounting plate
4 pcs.
4 pcs. (2 pcs.) *
4 pcs.
4 pcs. (2 pcs.) *
4 pcs.
4 pcs. (2 pcs.) *
4 pcs.
* ( ): When using the cutout for mounting B.
20 mm (0.79 in.) or more
40 mm (1.57 in.) or more

Advertisement

loading