Inspection and maintenance
Installation of the control unit on the service unit:
1. Check whether or not the service unit (5) goes
with the control unit (1) (model designation and
colour of the arresting hook).
2. Check whether or not the sealing mat (11)
and the contact springs (13) are clean,
dry, and free from impurities.
3. Introduce the sensor (12)
into the sensor tube plate (14).
4. Hang the hook (15) of the control unit (1)
in the sensor tube plate (14).
5. Press the control unit (1) against the
service unit (5) and snap into place.
Start-up subsequent to maintenance measures:
Always carry out prior to the start-up:
Leak test of the screwed connector
Check of the electrical connections
Check of the correct engagement of the control unit