Download Print this page

Assa Abloy Corbin Russwin Access 700 ML20700 TCPWI1 Series Installation Instructions Manual page 10

Mortise lockset

Advertisement

ML20700 PWI/PIP Series Mortise Lock
5.
Install Standard Lever Trim Instructions (continued):
Step 4A
Step 5 -
Align adjustment bolt with threaded hole in lever
Adjustment bolt needs
to be threaded in farther.
Step 6
Notes:
Unthread Adjustment Bolt approximately four turns
for a good starting point (After being fully tightened)
Make sure O/S lever is fully inserted into adapter
plate before aligning adjustment bolt.
Copyright © 2015 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Installation Instructions (Continued)
Inside Face of Door
Step 4B
Use Correct Spindle Orientation
STANDARD
Lever
Adjustment bolt needs
to be unthreaded.
10
MUSÉO
Good
Bad
Adjustment bolt
fully aligned.
Inside Face of Door