GPD-100
Instruction Manual
Headquarters / Engineering research laboratory :
23 Gunpo Advance d Industry 1-ro(Bugok-dong), Gunpo-si, Gyeonggi-do
Tel +82-31-490-0800 Fax +82-31-490-0801
Yeongnam business office / Plant :
55 Gonghangap-gil 85beon-gil, Gangseogu, Busan Metropolitan City
Tel +51-973-8518 Fax +51-973-8519
E-mail : info@gastron.com
www.gastron.com
Read in detail for correct use.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GPD-100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GASTRON GPD-100

  • Page 1 Headquarters / Engineering research laboratory : 23 Gunpo Advance d Industry 1-ro(Bugok-dong), Gunpo-si, Gyeonggi-do Tel +82-31-490-0800 Fax +82-31-490-0801 Yeongnam business office / Plant : 55 Gonghangap-gil 85beon-gil, Gangseogu, Busan Metropolitan City Tel +51-973-8518 Fax +51-973-8519 E-mail : info@gastron.com www.gastron.com Read in detail for correct use.
  • Page 2 Gas detectors satisfying customers. From now on, solve all anguishes concerning Gas detector with the products of Gastron Co. Ltd, We Gastron Co. will take a responsibility and give you satisfaction. In the present instruction manual, operation method for Gas detector as well as simple methods for maintenance and repair, etc.
  • Page 3: Table Of Contents

    GPD-100 Contents Contents www.gastron.com Instruction Manual 04_05 1. Overview · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·...
  • Page 4: Overview

    Body of GPD-100 has enclosure made of plastic (Polycarbonate) material. Flow Rate 100 ~ 1,000 ml (Normal 300~500ml / min) GPD-100 has Sample pump embedded according to the method where leaked gas is inhaled by using a Pump. The Gas Sample Line Less than 5m ( 1/4" Tube)
  • Page 5: Electricalspecifications (Standard Type)

    See sensor specifications Transmitter -20 to 50 ℃ Storage Temperature Sensor See sensor specifications Transmitter 5 to 99% RH (Non-condensing) Operation Humidity Sensor See sensor specifications Pressure Range 90 to 110KPa Max. air velocity 6m/s [Figure 2. Components of GPD-100]...
  • Page 6: Configuration Of Front Face Unit Display

    GPD-100 4. Name and description of each part 4. Name and description of each part www.gastron.com Instruction Manual 10_11 4.2. Configuration of front face unit Display NAME DESCRIPTIONS Zero, Span icon Display Zero, Span Mode state upon calibration Display of gas concentration...
  • Page 7: Operation

    GPD-100 5. Operation 5. Operation www.gastron.com Instruction Manual 12_13 5.1. Connection of Sampling Probe 5.4. Setting of inside mode(Mode Configuration) ■ Connect the sampling probe (1/4 "Teflon tube) to the Gas Inlet port. - When "RUN/MODE" Key is pushed for more than 2sec in the state of displaying "Stby" (Stand by).
  • Page 8: How To Use Log Mode

    GPD-100 5. Operation 5. Operation www.gastron.com Instruction Manual 14_15 5.6. How to use log mode ■ FILES in 3 forms remain as log in the folder generated by the unit of hour-minute-second. ■ Connect SD memory to PC to read data saved in SD card after use of log mode ■...
  • Page 9 GPD-100 5. Operation 5. Operation www.gastron.com Instruction Manual 16_17 5.6.1. Gas measurement log file CATEGORY SUBDIVISION DESCRIPTION REMARKS Device Name Product model name ■ Measurement files are saved under the name of GAS00.txt, F/W Version Firmware version and opened by using Notepad or Text editor.
  • Page 10: System Mode

    GPD-100 6. System Mode 6. System Mode www.gastron.com Instruction Manual 18_19 6.1. Mode configuration CLASSIFICATION MENU DISPLAY DESCRIPTION REMARKS Execution setting for ■ The relevant equipment is comprised of the menu in the following form. YES/no span calibration Setting for span...
  • Page 11 GPD-100 6. System Mode 6. System Mode www.gastron.com Instruction Manual 20_21 - Address setting function message "Add" is displayed to set the recognition number in data communication. - It is a setting function mode for voltage used by Pyrolyzer , and is displayed as "Py-V".
  • Page 12: Zero Calibration

    GPD-100 6. System Mode 6. System Mode www.gastron.com Instruction Manual 22_23 - Setting function message for High scale as the function for setting the maximum value for gas concentration display is displayed as "H-SL". - When "RUN/MODE" Key is pushed, setting function for High scale is entered into, - High scale value is set in the range set by domestic regulations upon product shipment.
  • Page 13: Span Calibration

    GPD-100 6. System Mode 6. System Mode www.gastron.com Instruction Manual 24_25 6.6. Span Calibration - Push "RUN/MODE" Key in "CALb" mode to enter into calibration mode. - Alarm latch type has 2 modes of "on" and "0FF", with " on" and "0FF" being changed whenever - When "ZERO"...
  • Page 14: Log Save Mode

    GPD-100 6. System Mode 6. System Mode www.gastron.com Instruction Manual 26_27 - It shows a type of external memory. If "RUN/MODE" Key, it is shifted to the next mode. - It is a mode where the direction for operation of Alarm1 is set, and "2H" or "2L" is displayed whenever "UP"...
  • Page 15: Troubleshooting

    GPD-100 7. Troubleshooting 7. Troubleshooting www.gastron.com Instruction Manual 28_29 7.1. Fault List 발생 원인 대처 방안 1) Revise parameters and recalibrate after execution FAULT DESCRIPTION & CONDITION 발생원인 of memory initialization Sensor Cartridge EEPROM defective When Sensor Cartridge was not mounted to the body or is...
  • Page 16: Outline Drawing And Dimensions

    8. Outline drawing and Dimensions VERSION CONTENTS DATE Rev0.0 Manual revised initially 2011.12.31 * modify GPD-100 image in page 1 * add Battery status Rev0.1 2011.12.21 * add Flow calibration method * Battery Spec 4.3A -> 4.4A Rev1.0 Factory Mode manual separated 2016.09.23...