Graco Reactor A-XP Series Operation page 22

Air powered, heated, plural component proportioner
Hide thumbs Also See for Reactor A-XP Series:
Table of Contents

Advertisement

Startup
i.
Hold
to view heater control circuit board
temperature.
j.
Manual current control mode only:
When in manual current control mode, monitor hose
temperature with thermometer. Install per instructions
below. Thermometer reading must not exceed 160°F
(71°C). Never leave machine unattended when in
manual current control mode.
If FTS is disconnected or display shows diag-
nostic code E04, turn main power switch OFF
then ON
code and enter manual current control mode.
display will show current to hose. Current
is not limited by target temperature.
To prevent overheating, install hose thermome-
ter close to gun end, within operator view. Insert
thermometer through foam cover of A compo-
nent hose so stem is next to inner tube. Ther-
mometer reading will be about 20°F less than
actual fluid temperature.
If thermometer reading exceeds 160°F (71°C),
reduce current with
22
to clear diagnostic
key.
9. Check Cycle Count
a. To display cycle count, press
To clear counter, press
onds.
.
and hold for 3 sec-
312407C