Graco Reactor A-XP Series Operation page 18

Air powered, heated, plural component proportioner
Hide thumbs Also See for Reactor A-XP Series:
Table of Contents

Advertisement

Setup
9. Connect heated hose
See Heated Hose manual 309572 for detailed
instructions on connecting heated hoses.
CAUTION
The fluid temperature sensor (C) and whip hose (D)
must be used with heated hose, see page 17. Hose
length, including whip hose, must be 60 ft (18.3 m)
minimum.
a. Turn main power OFF
b. Assemble heated hose sections, FTS, and whip
hose.
c. Connect A and B hoses to A and B outlets on
Reactor fluid manifold (FM). Hoses are color
coded: red for component A (ISO), blue for com-
ponent B (RES). Fittings are sized to prevent
connection errors.
FM
N
A
Manifold hose adapters (N, P) allow use of 1/4 in.
and 3/8 in. ID fluid hoses. To use 1/2 in. (13 mm) ID
fluid hoses, remove adapters from fluid manifold
and install as needed to connect whip hose.
d. Connect cables (Y). Connect electrical connec-
tors (V). Be sure cables have slack when hose
18
.
10. Close gun fluid manifold valves A and B
11. Connect whip hose to gun fluid mani-
P
B
ti9878a
12. Pressure check hose
See hose manual. Pressure check for leaks. If no leaks,
wrap hose and electrical connections to protect from
damage.
bends. Wrap cable and electrical connections
with electrical tape.
Y
fold
Do not connect manifold to gun.
V
ti9881a
ti2411a
ti2417a
312407C

Advertisement

Table of Contents
loading

Table of Contents