7. Connect pressure relief lines
Do not install shutoffs downstream of the PRESSURE
RELIEF/SPRAY valve outlets (BA, BB). The valves
function as overpressure relief valves when set to
SPRAY
. Lines must be open so valves can
automatically relieve pressure when machine is oper-
ating.
If circulating fluid back to the supply drums, use high
pressure hose rated to withstand the maximum work-
ing pressure of this equipment.
a. Recommended: Connect high pressure hose
(R) to relief fittings (BA, BB) of both PRES-
SURE RELIEF/SPRAY valves, Route hose back
to component A and B drums. See F
9.
SA
BA
R
b. Alternately: Secure supplied bleed tubes (N) in
grounded, sealed waste containers (H). See
F
. 2, page 10.
IG
8. Install Fluid Temperature Sensor (FTS)
The Fluid Temperature Sensor (FTS) is supplied. Install
FTS between main hose and whip hose. See Heated
Hose manual 309572 for instructions.
312407C
. 1, page
IG
SB
R
ti9880a
BB
Setup