1.4.e In-Line Chlorine Feeders
Place in-line chlorinators downstream from the heat pump and as low in elevation as possible.
If an erosion type feeder is used, it is recommended that a Hartford Loop be installed to protect internal heat
l
pump components.
A Hartford Loop is not necessary with a Salt Chlorine Generator.
l
Heat Pump with Hartford Loop
1.4.f Water Flow Rates
Maintain water flow rates as indicated. Please note, these specifications relate to the heat pump only. Code-
specified whole system turnover rates must be satisfied.
NOTICE
Water flow exceeding maximum flow rates will negatively affect the total pool filtration performance and may
l
damage the heat pump. This will not be covered under the equipment warranty.
Water Source
MODEL SOURCE
Source-Side
WS03
Pool / Spa
Page - 14
Failure to heed the following may result in damage to equipment.
HEAT EXCHANGER TYPE
®
Titanium ThermoLink
Cupronickel
®
Titanium ThermoLink
FLOW RATES
MINIMUM
20 GPM (75.7 L/min)
10 GPM (37.9 L/min)
30 GPM (113.6 L/min) 70 GPM (265 L/min)
MAXIMUM
70 GPM (265 L/min)
14 GPM (53 L/min)