Test Mode Timer Table - Panasonic CS-PC30EKF Service Manual

Table of Contents

Advertisement

12.2.2. CLOCK
• To change the remote control's clock-hour and minute.
- Press once to enter the clock setting mode.
- Use timer increment button timer decrement button to change the time.
- Press once again to exit the setting mode.
• To change the time format (24 hours & 12 hours timer display).
- Press for more than 5 seconds.
12.2.3. RESET
• To clear and restore the remote control setting to factory default.
- Press for once to clear the memory.
12.2.4. TIMER " "
• Press continuously for 5 seconds, LED intensity for Remote Control dimmer code is transmitted.
• Above condition will not happen when Timer is set.
12.2.5. TIMER " "
• Press continuously for 10 seconds, set the operation and display changes as Celsius or Fahrenheit.
• Above condition will not happen when Timer is set.

12.3. Test Mode Timer Table

Name
Real Timer
Timer Delay Safety Control
Forced Operation
Timer Save Control
Anti-Freezing
Auto Mode Judgement
Soft Dry
Deodorizing Control
Comp. Reverse Rotation Detection
Comp./ Fan Motor Delay Timer
Random Auto Restart Control
OFF
ON
Cooling
Soft Dry
Test Mode
Time
(When test point
Short-circuited)
1 hr.
1 min.
10 min.
10 sec.
1 min.
1 sec.
2 min. 58 sec.
0 sec.
60 sec.
0 sec.
7 min.
4.2 sec.
4 min.
0 sec.
20 sec.
0 sec.
6 min.
36 sec.
10 min.
60 sec.
40 sec.
4 sec.
70 sec.
7 sec.
20 sec.
2 sec.
180 sec.
18 sec.
40 sec.
4 sec.
360 sec.
36 sec.
5 min.
30 sec.
2 min.
0 sec.
1.6 sec.
0 sec.
0 ~ 62 sec.
0 ~ 6.2 sec.
37
Remarks
Soft Dry: 10 min. operation
Com. ON 5 min. and above

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-pc30ekfCs-pc36ekfCu-pc36ekf

Table of Contents