FortiGate-7060E System Management Modules
Use the following IPMI command to change the SMM password:
sudo ipmitool -I lanplus -H <mgmt-ip> -k gkey -U <username> -P <password> user set password 2
<password>
To perform an operation on a module according to its chassis slot include the
command. For example, to list the sensors on the FIM module in chassis slot 2 (0x82), use the following IPMI
command:
sudo ipmitool -I lanplus -H <mgmt-ip> -k gkey -U <username> -P <password0> -t 0x82 sensor

FortiGate-7060E chassis slots IPMB addresses

The following table lists the IPMB addresses of the FortiGate-7060E chassis slots.
Chassis slot number
SMM 1
SMM 2
5
3
1
2
4
6
You can use the IPMB address or chassis slot number to reference a chassis slot when entering commands in the SMM
CLI. For example, enter either of the following commands to display sensor readings for the FIM in slot 2:
sensor 0x84
sensor 2
When command syntax descriptions in this chapter include the <slot> variable you can replace it with a slot number (1 to
6) or an IPMB address number (0x82 to 0x8C).

Rebooting an FIM or FPM from the SMC SDI CLI

A common use of the SMC SDI CLI is being able to remotely reboot a FIM or FPM.
From any SMC SDI CLI use the following command to reboot the FPM in slot 3:
mc reset 3 warm
Use the following command to power off the FPM in slot 4:
fru deactivate 4
FortiGate-7060E 6.4.2 System Guide
Name
MGMT1
MGMT2
FPM5
FPM3
FIM1
FIM2
FPM4
FPM6
Fortinet Technologies Inc.
-t <slot> parameter in the IPMI
IPMB Address (FRUID)
if active 0x20, if passive (the
default) 0x22
if active (the default) 0x20, if
passive 0x22
0x8A
0x86
0x82
0x84
0x88
0x8C
55