FortiGate-7060E hardware assembly and rack mounting
FortiGate-7060E cooling air flow and minimum air flow clearance
Front
100 mm
Cool air
Intake
Cool air enters the chassis through the chassis front panel and warm air exhausts out the back. For optimal cooling,
allow 100 mm of clearance at the front and back of the chassis.
Inserting FIMs and FPMs
All FortiGate-7060E chassis are shipped with a protective front panel installed in the chassis to protect internal chassis
components. This panel must be removed before you install FIMs and FPMs.
Insert FIMs into chassis slots 1 and 2. Insert FPMs into chassis slots 3, 4, 5, and 6.
FortiGate-7060E 6.4.2 System Guide
FortiGate-7121F chassis (side View)
675 mm
Fortinet Technologies Inc.
Back
100 mm
Fan
Trays
Warm Air
Exhaust
Fan
Trays
28