Graco TapeLazer HP Automatic Operation, Parts page 47

Table of Contents

Advertisement

Operating Condition #3
Tape application assembly is in application
position. Carriage is in the raised position,
see Tape Application Assembly
Positions, page 24.
Output '1' = ON
Output '2' = ON
Output 'C' = ON
Operating Condition #4
Tape application assembly is in secondary
position. Carriage is in the raised position,
see Tape Application Assembly
Positions, page 24.
Output '1' = ON
Output '2' = OFF
Output 'C' = ON
3A8108A
Troubleshooting
Notes:
1.
To energize solenoid outputs '1' and '2',
press the tape application button once.
2.
To energize solenoid output '1' by itself,
press the tape application button twice.
3.
To energize solenoid output 'C', use the
carriage raise/lower switch.
4.
To energize outputs '1' and '2' either
solid or skip line must be selected and
highlighted red on the display.
If unit does not function as described
above, check the following:
1.
Mechanical jam. Check to make sure
there is no obstruction or binding that is
restricting movement. Make sure that
the carriage locking pins are in the
retracted position.
2.
Wiring is incorrect. Check Wiring
Diagram, page 64.
3.
Air line routing is incorrect. Check Air
Line Schematic, page 62. When
connecting air lines follow the Air Line
Connection Sequence, page 63.
4.
Unit has a short circuit. See Diagnosing
a Short Circuit, page 48.
5.
Unit has an open circuit. See
Diagnosing an Open Circuit, page 48.
6.
Solenoids are not functioning properly.
See To Check if Solenoids are
Functioning Properly, page 49.